Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Biscaldi, Thomas, l'Huillier, Romain, Milot, Laurent, N'Djin, W Apoutou
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866909889961394176
author Biscaldi, Thomas
l'Huillier, Romain
Milot, Laurent
N'Djin, W Apoutou
author_facet Biscaldi, Thomas
l'Huillier, Romain
Milot, Laurent
N'Djin, W Apoutou
contents Current interstitial techniques of tumor ablation face challenges that ultrasound technologies could meet. The ablation radius and directionality of the ultrasound beam could improve the efficiency and precision. Here, a 9gauge MR-compatible dual-mode ultrasound catheter prototype was experimentally evaluated for Ultrasound Imageguided High Intensity Focused Ultrasound (USgHIFU) conformal ablations. The prototype consisted of 64 piezocomposite linear array elements and was driven by an open research programmable dual-mode ultrasound platform. After verifying the US-image guidance capabilities of the prototype, the HIFU output performances (dynamic focusing and HIFU intensities) were quantitatively characterized, together with the associated 3D HIFU-induced thermal heating in tissue phantoms (using MR thermometry). Finally, the ability to produce robustly HIFU-induced thermal ablations in in-vitro liver was studied experimentally and compared to numerical modeling. Investigations of several HIFU dynamic focusing allowed overcoming the challenges of miniaturizing the device: mono-focal focusing maximized deep energy deposition, while multi-focal strategies eliminated grating lobes. The linear-array design of the prototype made it possible to produce interstitial ultrasound images of tissue and tumor mimics in situ. Multi-focal pressure fields were generated without grating lobes and transducer surface intensities reached up to Isapa =14 W$\bullet$cm -2 . Seventeen elementary thermal ablations were performed in vitro. Rotation of the catheter proved the directionality of ablation, sparing non-targeted tissue. This experimental proof of concept demonstrates the feasibility of treating volumes comparable to those of primary solid tumors with a miniaturized USgHIFU catheter whose dimensions are close to those of tools traditionally used in interventional radiology, while offering new functionalities.
format Preprint
id arxiv_https___arxiv_org_abs_2511_04207
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations
Biscaldi, Thomas
l'Huillier, Romain
Milot, Laurent
N'Djin, W Apoutou
Classical Physics
Current interstitial techniques of tumor ablation face challenges that ultrasound technologies could meet. The ablation radius and directionality of the ultrasound beam could improve the efficiency and precision. Here, a 9gauge MR-compatible dual-mode ultrasound catheter prototype was experimentally evaluated for Ultrasound Imageguided High Intensity Focused Ultrasound (USgHIFU) conformal ablations. The prototype consisted of 64 piezocomposite linear array elements and was driven by an open research programmable dual-mode ultrasound platform. After verifying the US-image guidance capabilities of the prototype, the HIFU output performances (dynamic focusing and HIFU intensities) were quantitatively characterized, together with the associated 3D HIFU-induced thermal heating in tissue phantoms (using MR thermometry). Finally, the ability to produce robustly HIFU-induced thermal ablations in in-vitro liver was studied experimentally and compared to numerical modeling. Investigations of several HIFU dynamic focusing allowed overcoming the challenges of miniaturizing the device: mono-focal focusing maximized deep energy deposition, while multi-focal strategies eliminated grating lobes. The linear-array design of the prototype made it possible to produce interstitial ultrasound images of tissue and tumor mimics in situ. Multi-focal pressure fields were generated without grating lobes and transducer surface intensities reached up to Isapa =14 W$\bullet$cm -2 . Seventeen elementary thermal ablations were performed in vitro. Rotation of the catheter proved the directionality of ablation, sparing non-targeted tissue. This experimental proof of concept demonstrates the feasibility of treating volumes comparable to those of primary solid tumors with a miniaturized USgHIFU catheter whose dimensions are close to those of tools traditionally used in interventional radiology, while offering new functionalities.
title Interstitial dual-mode ultrasound with a 3-mm MR-compatible catheter for image-guided HIFU and directional in-vitro tissue ablations
topic Classical Physics
url https://arxiv.org/abs/2511.04207