Development and characterization of MPGD-based transition radiation detectors

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kasper, Lauren, Austregesilo, Alexander, Barbosa, Fernando, Dickover, Cody, Furletov, Sergey, Furletova, Yulia, Gnanvo, Kondo, Greene, Senta Vicki, Pentchev, Lubomir, Tarafdar, Sourav, Velkovska, Julia
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866912930672410624
author Kasper, Lauren
Austregesilo, Alexander
Barbosa, Fernando
Dickover, Cody
Furletov, Sergey
Furletova, Yulia
Gnanvo, Kondo
Greene, Senta Vicki
Pentchev, Lubomir
Tarafdar, Sourav
Velkovska, Julia
author_facet Kasper, Lauren
Austregesilo, Alexander
Barbosa, Fernando
Dickover, Cody
Furletov, Sergey
Furletova, Yulia
Gnanvo, Kondo
Greene, Senta Vicki
Pentchev, Lubomir
Tarafdar, Sourav
Velkovska, Julia
contents Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge effects, motivating the replacement of the amplification stage with MicroPattern Gaseous Detectors (MPGDs). This work explores different MPGD technologies - Gas Electron Multiplier (GEM), Micro-Mesh Gaseous Structure (Micromegas), and Resistive Micro-Well ($μ$RWELL) - as alternative TRD amplification stages. We report on the design, construction, and in-beam characterization of multiple MPGD-based TRD prototypes exposed to 3-20 GeV mixed electron-hadron beams at the Fermilab Test Beam Facility and at the CERN SPS H8 beamline. Each detector consisted of a multi-layered radiator, an approximately 2 cm deep drift region, an MPGD amplification stage optimized for X-ray transition radiation detection in a Xe:CO$_{2}$ (90:10) gas mixture, and a two-dimensional readout. The GEM-based TRD prototype achieved a pion suppression factor of about 8 at 90% electron efficiency, while the Micromegas-based prototype - with an added GEM preamplification layer - demonstrated improved operational stability and clear TR photon discrimination. The $μ$RWELL prototype achieved stable operation but limited signal gain. Geant4-based studies confirmed the observed trends and highlighted the sensitivity of the TR yield to cathode material and radiator configuration. These studies represent the first in-beam measurements of Micromegas- and $μ$RWELL-based TRDs, along with discussion of the performance capabilities of a triple-GEM-TRD. The results demonstrate the feasibility of MPGDs as scalable, high-rate amplification structures for next-generation TRD applications.
format Preprint
id arxiv_https___arxiv_org_abs_2511_05453
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Development and characterization of MPGD-based transition radiation detectors
Kasper, Lauren
Austregesilo, Alexander
Barbosa, Fernando
Dickover, Cody
Furletov, Sergey
Furletova, Yulia
Gnanvo, Kondo
Greene, Senta Vicki
Pentchev, Lubomir
Tarafdar, Sourav
Velkovska, Julia
Instrumentation and Detectors
Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge effects, motivating the replacement of the amplification stage with MicroPattern Gaseous Detectors (MPGDs). This work explores different MPGD technologies - Gas Electron Multiplier (GEM), Micro-Mesh Gaseous Structure (Micromegas), and Resistive Micro-Well ($μ$RWELL) - as alternative TRD amplification stages. We report on the design, construction, and in-beam characterization of multiple MPGD-based TRD prototypes exposed to 3-20 GeV mixed electron-hadron beams at the Fermilab Test Beam Facility and at the CERN SPS H8 beamline. Each detector consisted of a multi-layered radiator, an approximately 2 cm deep drift region, an MPGD amplification stage optimized for X-ray transition radiation detection in a Xe:CO$_{2}$ (90:10) gas mixture, and a two-dimensional readout. The GEM-based TRD prototype achieved a pion suppression factor of about 8 at 90% electron efficiency, while the Micromegas-based prototype - with an added GEM preamplification layer - demonstrated improved operational stability and clear TR photon discrimination. The $μ$RWELL prototype achieved stable operation but limited signal gain. Geant4-based studies confirmed the observed trends and highlighted the sensitivity of the TR yield to cathode material and radiator configuration. These studies represent the first in-beam measurements of Micromegas- and $μ$RWELL-based TRDs, along with discussion of the performance capabilities of a triple-GEM-TRD. The results demonstrate the feasibility of MPGDs as scalable, high-rate amplification structures for next-generation TRD applications.
title Development and characterization of MPGD-based transition radiation detectors
topic Instrumentation and Detectors
url https://arxiv.org/abs/2511.05453