Non-invasive load measurement in the human tibia via spectral analysis of flexural waves

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Yawar, Ali, Aslan, Daniel H., Lieberman, Daniel E.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911637281177600
author Yawar, Ali
Aslan, Daniel H.
Lieberman, Daniel E.
author_facet Yawar, Ali
Aslan, Daniel H.
Lieberman, Daniel E.
contents Forces transmitted by bones are routinely studied in human biomechanics, but it is challenging to measure them non-invasively, especially outside of laboratory settings. We introduce a technique for non-invasive, in vivo measurement of tibial compressive force using flexural waves propagating in the tibia. Modelling the tibia as an axially compressed Euler-Bernoulli beam, we show that tibial flexural waves have load-dependent frequency spectra. Specifically, under physiological conditions, peak locations in the wave acceleration spectra vary linearly with the compressive force on the tibia and may be used as proxies for the compressive force. We test the validity of this technique using a proof-of-concept wearable system that generates flexural waves via a skin-mounted mechanical transducer and measures the spectra of these waves using a skin-mounted accelerometer. In agreement with beam theory, data from 9 participants demonstrate linear relationships between tibial compressive force and spectral peak location, with Pearson correlation coefficients $r=0.82 - 0.99$ (mean $r=0.93$) for medial-lateral swaying and $r=0.81 - 0.98$ (mean $r=0.93$) for walking trials. This flexural wave-based technique could give rise to a new class of wearable sensors for non-invasive physiological bone load monitoring and measurement, impacting research in human locomotion and sports medicine.
format Preprint
id arxiv_https___arxiv_org_abs_2511_06140
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Non-invasive load measurement in the human tibia via spectral analysis of flexural waves
Yawar, Ali
Aslan, Daniel H.
Lieberman, Daniel E.
Quantitative Methods
Forces transmitted by bones are routinely studied in human biomechanics, but it is challenging to measure them non-invasively, especially outside of laboratory settings. We introduce a technique for non-invasive, in vivo measurement of tibial compressive force using flexural waves propagating in the tibia. Modelling the tibia as an axially compressed Euler-Bernoulli beam, we show that tibial flexural waves have load-dependent frequency spectra. Specifically, under physiological conditions, peak locations in the wave acceleration spectra vary linearly with the compressive force on the tibia and may be used as proxies for the compressive force. We test the validity of this technique using a proof-of-concept wearable system that generates flexural waves via a skin-mounted mechanical transducer and measures the spectra of these waves using a skin-mounted accelerometer. In agreement with beam theory, data from 9 participants demonstrate linear relationships between tibial compressive force and spectral peak location, with Pearson correlation coefficients $r=0.82 - 0.99$ (mean $r=0.93$) for medial-lateral swaying and $r=0.81 - 0.98$ (mean $r=0.93$) for walking trials. This flexural wave-based technique could give rise to a new class of wearable sensors for non-invasive physiological bone load monitoring and measurement, impacting research in human locomotion and sports medicine.
title Non-invasive load measurement in the human tibia via spectral analysis of flexural waves
topic Quantitative Methods
url https://arxiv.org/abs/2511.06140