Temperature Dependence of the Time Resolution in a SiPM-Readout Plastic Scintillator for Cosmic-Ray Applications

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Castillo, José Reyes, Salazar, Saúl Aguilar, Coral, Diego Mauricio Gomez
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909900472320000
author Castillo, José Reyes
Salazar, Saúl Aguilar
Coral, Diego Mauricio Gomez
author_facet Castillo, José Reyes
Salazar, Saúl Aguilar
Coral, Diego Mauricio Gomez
contents Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these systems can be affected by temperature variations encountered in flight. In this work, a time-of-flight (TOF) prototype consisting of a BC418 plastic scintillator bar coupled to Onsemi MICROFC-30050 SiPMs was constructed and tested under a controlled thermal environment between -20 and 20$^{\circ}$C. Electrons from a $^{90}\text{Sr}$ source were used as a beam, and a dedicated differential preamplifier and coincidence triggering were implemented to study the detector response. A minimum time resolution of 160ps was achieved at an overvoltage of 3V, remaining stable across the tested temperature range and uniform along the scintillator bar.
format Preprint
id arxiv_https___arxiv_org_abs_2511_10041
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Temperature Dependence of the Time Resolution in a SiPM-Readout Plastic Scintillator for Cosmic-Ray Applications
Castillo, José Reyes
Salazar, Saúl Aguilar
Coral, Diego Mauricio Gomez
Instrumentation and Detectors
Balloon- and space-borne cosmic-ray experiments employ plastic scintillators read out by silicon photomultipliers (SiPMs) to achieve picosecond-level time resolutions for triggering and particle identification. The performance of these systems can be affected by temperature variations encountered in flight. In this work, a time-of-flight (TOF) prototype consisting of a BC418 plastic scintillator bar coupled to Onsemi MICROFC-30050 SiPMs was constructed and tested under a controlled thermal environment between -20 and 20$^{\circ}$C. Electrons from a $^{90}\text{Sr}$ source were used as a beam, and a dedicated differential preamplifier and coincidence triggering were implemented to study the detector response. A minimum time resolution of 160ps was achieved at an overvoltage of 3V, remaining stable across the tested temperature range and uniform along the scintillator bar.
title Temperature Dependence of the Time Resolution in a SiPM-Readout Plastic Scintillator for Cosmic-Ray Applications
topic Instrumentation and Detectors
url https://arxiv.org/abs/2511.10041