Pulsed heterodyne Brillouin detection enables high-resolution epi-detected biomechanical microscopy and endoscopy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Du, Zixuan, Yao, Shuai, Qi, Yun, Zhang, Jinrui, You, Junlin, Liu, Yangxuan, Mi, Ting, Luo, Yun, Cai, Shiqing, Xie, Jingjing, Yang, Weibing, Yang, Zhisheng, Zhang, Long, Chen, Weibiao, Yang, Fan
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917527409393664
author Du, Zixuan
Yao, Shuai
Qi, Yun
Zhang, Jinrui
You, Junlin
Liu, Yangxuan
Mi, Ting
Luo, Yun
Cai, Shiqing
Xie, Jingjing
Yang, Weibing
Yang, Zhisheng
Zhang, Long
Chen, Weibiao
Yang, Fan
author_facet Du, Zixuan
Yao, Shuai
Qi, Yun
Zhang, Jinrui
You, Junlin
Liu, Yangxuan
Mi, Ting
Luo, Yun
Cai, Shiqing
Xie, Jingjing
Yang, Weibing
Yang, Zhisheng
Zhang, Long
Chen, Weibiao
Yang, Fan
contents Brillouin microscopy enables non-contact, three-dimensional mapping of viscoelasticity in living systems, yet two long-standing limitations have constrained its biological reach: the lack of high-spectral-resolution epi-detection and the absence of practical fiber-compatible implementations. Here we introduce pulsed heterodyne Brillouin detection (PHBD), a coherent time-domain scheme addressing both challenges. By combining high-peak-power pulsed excitation with shot-noise-limited detection, PHBD reduces the optical dose by approximately two orders of magnitude relative to continuous-wave heterodyne approaches. In an epi-microscope configuration, PHBD attains a spectral resolution of 27 MHz, a tenfold improvement over state-of-the-art Brillouin microscopes, enabling high-specificity, low-phototoxicity imaging of live cells and complex tissues. In an endoscopic configuration, coherent gating rejects parasitic Brillouin background from the delivery fiber, accelerating acquisition by two to three orders of magnitude over previous fiber-optic Brillouin endoscopes. Together, these capabilities establish a unified platform for single-ended, fiber-compatible Brillouin biomechanics, extending mechanical imaging and spectroscopy from cells to deep tissues via minimally invasive probes.
format Preprint
id arxiv_https___arxiv_org_abs_2511_12252
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Pulsed heterodyne Brillouin detection enables high-resolution epi-detected biomechanical microscopy and endoscopy
Du, Zixuan
Yao, Shuai
Qi, Yun
Zhang, Jinrui
You, Junlin
Liu, Yangxuan
Mi, Ting
Luo, Yun
Cai, Shiqing
Xie, Jingjing
Yang, Weibing
Yang, Zhisheng
Zhang, Long
Chen, Weibiao
Yang, Fan
Optics
Brillouin microscopy enables non-contact, three-dimensional mapping of viscoelasticity in living systems, yet two long-standing limitations have constrained its biological reach: the lack of high-spectral-resolution epi-detection and the absence of practical fiber-compatible implementations. Here we introduce pulsed heterodyne Brillouin detection (PHBD), a coherent time-domain scheme addressing both challenges. By combining high-peak-power pulsed excitation with shot-noise-limited detection, PHBD reduces the optical dose by approximately two orders of magnitude relative to continuous-wave heterodyne approaches. In an epi-microscope configuration, PHBD attains a spectral resolution of 27 MHz, a tenfold improvement over state-of-the-art Brillouin microscopes, enabling high-specificity, low-phototoxicity imaging of live cells and complex tissues. In an endoscopic configuration, coherent gating rejects parasitic Brillouin background from the delivery fiber, accelerating acquisition by two to three orders of magnitude over previous fiber-optic Brillouin endoscopes. Together, these capabilities establish a unified platform for single-ended, fiber-compatible Brillouin biomechanics, extending mechanical imaging and spectroscopy from cells to deep tissues via minimally invasive probes.
title Pulsed heterodyne Brillouin detection enables high-resolution epi-detected biomechanical microscopy and endoscopy
topic Optics
url https://arxiv.org/abs/2511.12252