Approximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lenander, Emma Y., Schack, Silas B., Lefmann, Kim, Rønnow, Henrik M.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866914169247236096
author Lenander, Emma Y.
Schack, Silas B.
Lefmann, Kim
Rønnow, Henrik M.
author_facet Lenander, Emma Y.
Schack, Silas B.
Lefmann, Kim
Rønnow, Henrik M.
contents We present an analytic convoluted-gap function, eq. 11 in the manuscript, for fitting dispersion gaps measured on triple-axis spectrometers (TAS). At the gap, the instrumental resolution skews the signal, producing a high-energy tail that complicates fitting. Our function assumes an instrumental $Q$-resolution with two equal wide and one narrow direction (typical of focused TAS instruments), and a parabolic dispersion at the gap, which is exact for quadratic and accurate for linear dispersions if the resolution is moderate. We demonstrate, that our function outperforms previous methods of fitting a gap, by giving a better fit and more accurate gap determination, seen in figure 4. Here, the anti-ferromagnetically gapped material; MnF$_2$ is simulated in a double-focusing TAS instrument. We also tested our function on experimental data on MnF$_2$ from a TAS-like instrument, where we reproduce the gap size from previous accurate experimentally determined measurements. The function is simple to implement, converges reliably, and we recommend its use for future gap fitting on TAS data.
format Preprint
id arxiv_https___arxiv_org_abs_2511_19144
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Approximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer
Lenander, Emma Y.
Schack, Silas B.
Lefmann, Kim
Rønnow, Henrik M.
Instrumentation and Detectors
Other Condensed Matter
We present an analytic convoluted-gap function, eq. 11 in the manuscript, for fitting dispersion gaps measured on triple-axis spectrometers (TAS). At the gap, the instrumental resolution skews the signal, producing a high-energy tail that complicates fitting. Our function assumes an instrumental $Q$-resolution with two equal wide and one narrow direction (typical of focused TAS instruments), and a parabolic dispersion at the gap, which is exact for quadratic and accurate for linear dispersions if the resolution is moderate. We demonstrate, that our function outperforms previous methods of fitting a gap, by giving a better fit and more accurate gap determination, seen in figure 4. Here, the anti-ferromagnetically gapped material; MnF$_2$ is simulated in a double-focusing TAS instrument. We also tested our function on experimental data on MnF$_2$ from a TAS-like instrument, where we reproduce the gap size from previous accurate experimentally determined measurements. The function is simple to implement, converges reliably, and we recommend its use for future gap fitting on TAS data.
title Approximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer
topic Instrumentation and Detectors
Other Condensed Matter
url https://arxiv.org/abs/2511.19144