Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Yi, Minseok, Lee, Daehee, Gola, Alberto, Merzi, Stefano, Penna, Michele, Cherry, Simon R., Lee, Jae Sung, Kwon, Sun Il
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909925406408704
author Yi, Minseok
Lee, Daehee
Gola, Alberto
Merzi, Stefano
Penna, Michele
Cherry, Simon R.
Lee, Jae Sung
Kwon, Sun Il
author_facet Yi, Minseok
Lee, Daehee
Gola, Alberto
Merzi, Stefano
Penna, Michele
Cherry, Simon R.
Lee, Jae Sung
Kwon, Sun Il
contents Bismuth germanate (BGO) is gaining renewed attention as a viable material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET) detectors. While single-crystal studies have demonstrated excellent timing resolution by leveraging prompt Cherenkov photons, practical detector modules based on pixelated arrays introduce a high prevalence of inter-crystal scattering (InterCS) events, complicating timing accuracy. In this study, we experimentally investigated the impact of InterCS on BGO Cherenkov timing using a dual-pixel detector coupled to a segmented SiPM readout. Events were classified into full-energy deposition (FED; primary crystal 511 keV absorption), InterCS, and penetration types via energy-weighted positioning and validated using GATE simulations, which also revealed that over 25% of the experimentally identified full-energy events involved intra-crystal scatter (IntraCS). For InterCS events, the optimal timestamp selection was achieved by choosing the earlier of the two timestamps, yielding a coincidence timing resolution of 221 ps FWHM (831 ps FWTM)-markedly worse than the 184 ps (603 ps FWTM) obtained for FED events. Furthermore, prompt photon yield was found to decrease measurably due to energy splitting: InterCS events averaged 4.73 detected photons in the first 1 ns, compared to 5.76 for FED events. These results emphasize the importance of incorporating time-aware, per-pixel timestamping strategies in pixelated BGO TOF-PET systems to maintain optimal timing performance in the presence of scatter.
format Preprint
id arxiv_https___arxiv_org_abs_2511_20864
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET
Yi, Minseok
Lee, Daehee
Gola, Alberto
Merzi, Stefano
Penna, Michele
Cherry, Simon R.
Lee, Jae Sung
Kwon, Sun Il
Instrumentation and Detectors
Medical Physics
Bismuth germanate (BGO) is gaining renewed attention as a viable material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET) detectors. While single-crystal studies have demonstrated excellent timing resolution by leveraging prompt Cherenkov photons, practical detector modules based on pixelated arrays introduce a high prevalence of inter-crystal scattering (InterCS) events, complicating timing accuracy. In this study, we experimentally investigated the impact of InterCS on BGO Cherenkov timing using a dual-pixel detector coupled to a segmented SiPM readout. Events were classified into full-energy deposition (FED; primary crystal 511 keV absorption), InterCS, and penetration types via energy-weighted positioning and validated using GATE simulations, which also revealed that over 25% of the experimentally identified full-energy events involved intra-crystal scatter (IntraCS). For InterCS events, the optimal timestamp selection was achieved by choosing the earlier of the two timestamps, yielding a coincidence timing resolution of 221 ps FWHM (831 ps FWTM)-markedly worse than the 184 ps (603 ps FWTM) obtained for FED events. Furthermore, prompt photon yield was found to decrease measurably due to energy splitting: InterCS events averaged 4.73 detected photons in the first 1 ns, compared to 5.76 for FED events. These results emphasize the importance of incorporating time-aware, per-pixel timestamping strategies in pixelated BGO TOF-PET systems to maintain optimal timing performance in the presence of scatter.
title Investigating the Timing Behavior of Compton Scattering in BGO for Time-of-Flight PET
topic Instrumentation and Detectors
Medical Physics
url https://arxiv.org/abs/2511.20864