Design and Measurements of mmWave FMCW Radar Based Non-Contact Multi-Patient Heart Rate and Breath Rate Monitoring System
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2025
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866917109917810688 |
|---|---|
| author | Benny, Jewel Mahajan, Pranjal Chatterjee, Srayan Sankar Wajid, Mohd Srivastava, Abhishek |
| author_facet | Benny, Jewel Mahajan, Pranjal Chatterjee, Srayan Sankar Wajid, Mohd Srivastava, Abhishek |
| contents | Recent developments in mmWave radar technologies have enabled the truly non-contact heart-rate (HR) and breath-rate (BR) measurement approaches, which provides a great ease in patient monitoring. Additionally, these technologies also provide opportunities to simultaneously detect HR and BR of multiple patients, which has become increasingly important for efficient mass monitoring scenarios. In this work, a frequency modulated continuous wave (FMCW) mmWave radar based truly non-contact multiple patient HR and BR monitoring system has been presented. Furthermore, a novel approach is also proposed, which combines multiple processing methods using a least squares solution to improve measurement accuracy, generalization, and handle measurement error. The proposed system has been developed using Texas Instruments' FMCW radar and experimental results with multiple subjects are also presented, which show >97% and >93% accuracy in the measured BR and HR values, respectively. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2511_21255 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Design and Measurements of mmWave FMCW Radar Based Non-Contact Multi-Patient Heart Rate and Breath Rate Monitoring System Benny, Jewel Mahajan, Pranjal Chatterjee, Srayan Sankar Wajid, Mohd Srivastava, Abhishek Systems and Control Robotics Signal Processing Recent developments in mmWave radar technologies have enabled the truly non-contact heart-rate (HR) and breath-rate (BR) measurement approaches, which provides a great ease in patient monitoring. Additionally, these technologies also provide opportunities to simultaneously detect HR and BR of multiple patients, which has become increasingly important for efficient mass monitoring scenarios. In this work, a frequency modulated continuous wave (FMCW) mmWave radar based truly non-contact multiple patient HR and BR monitoring system has been presented. Furthermore, a novel approach is also proposed, which combines multiple processing methods using a least squares solution to improve measurement accuracy, generalization, and handle measurement error. The proposed system has been developed using Texas Instruments' FMCW radar and experimental results with multiple subjects are also presented, which show >97% and >93% accuracy in the measured BR and HR values, respectively. |
| title | Design and Measurements of mmWave FMCW Radar Based Non-Contact Multi-Patient Heart Rate and Breath Rate Monitoring System |
| topic | Systems and Control Robotics Signal Processing |
| url | https://arxiv.org/abs/2511.21255 |