Influence of converter current limiting and prioritization on protection of highly IBR-penetrated networks

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Quintero, Andrés E., Lacerda, Vinícius A., Gomis-Bellmunt, Oriol, Davi, Moisés J. B. B., Oleskovicz, Mario
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917106534055936
author Quintero, Andrés E.
Lacerda, Vinícius A.
Gomis-Bellmunt, Oriol
Davi, Moisés J. B. B.
Oleskovicz, Mario
author_facet Quintero, Andrés E.
Lacerda, Vinícius A.
Gomis-Bellmunt, Oriol
Davi, Moisés J. B. B.
Oleskovicz, Mario
contents This paper investigates how grid-forming (GFM) and grid-following (GFL) control strategies in inverter-based resources (IBRs) influence line distance and differential protection in converter-dominated transmission systems. A modified IEEE 39-bus system is evaluated with GFM and GFL units equipped with low-voltage ride-through logic, current limiting, and positive- or negative-sequence prioritization. Distance protection is implemented with a mho characteristic, while line differential protection uses an alpha-plane approach. Results show that phase-to-ground loops in distance protection can substantially overestimate the fault location near the Zone-1 reach. For line differential protection, external faults may cause the operating point to briefly enter the trip region of the alpha-plane, even for the healthy-phase in ABG faults under GFL control and during the initial moments of the fault, demanding strong external security measures. These findings highlight that modern converter controls, together with current limitation and sequence-current prioritization, can compromise the reliability and security of traditional protection schemes.
format Preprint
id arxiv_https___arxiv_org_abs_2511_21385
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Influence of converter current limiting and prioritization on protection of highly IBR-penetrated networks
Quintero, Andrés E.
Lacerda, Vinícius A.
Gomis-Bellmunt, Oriol
Davi, Moisés J. B. B.
Oleskovicz, Mario
Systems and Control
This paper investigates how grid-forming (GFM) and grid-following (GFL) control strategies in inverter-based resources (IBRs) influence line distance and differential protection in converter-dominated transmission systems. A modified IEEE 39-bus system is evaluated with GFM and GFL units equipped with low-voltage ride-through logic, current limiting, and positive- or negative-sequence prioritization. Distance protection is implemented with a mho characteristic, while line differential protection uses an alpha-plane approach. Results show that phase-to-ground loops in distance protection can substantially overestimate the fault location near the Zone-1 reach. For line differential protection, external faults may cause the operating point to briefly enter the trip region of the alpha-plane, even for the healthy-phase in ABG faults under GFL control and during the initial moments of the fault, demanding strong external security measures. These findings highlight that modern converter controls, together with current limitation and sequence-current prioritization, can compromise the reliability and security of traditional protection schemes.
title Influence of converter current limiting and prioritization on protection of highly IBR-penetrated networks
topic Systems and Control
url https://arxiv.org/abs/2511.21385