Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Huang, Lijie, Yin, Jingyi, Zhang, Jingke, Lok, U-Wai, DeRuiter, Ryan M., Ji, Kaipeng, Zhao, Yanzhe, Wu, Tao, Krier, James D., Zhu, Xiang-yang, Bentall, Andrew J., Rule, Andrew D., Atwell, Thomas D., Lerman, Lilach O., Chen, Shigao, Huang, Chengwu
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909928100200448
author Huang, Lijie
Yin, Jingyi
Zhang, Jingke
Lok, U-Wai
DeRuiter, Ryan M.
Ji, Kaipeng
Zhao, Yanzhe
Wu, Tao
Krier, James D.
Zhu, Xiang-yang
Bentall, Andrew J.
Rule, Andrew D.
Atwell, Thomas D.
Lerman, Lilach O.
Chen, Shigao
Huang, Chengwu
author_facet Huang, Lijie
Yin, Jingyi
Zhang, Jingke
Lok, U-Wai
DeRuiter, Ryan M.
Ji, Kaipeng
Zhao, Yanzhe
Wu, Tao
Krier, James D.
Zhu, Xiang-yang
Bentall, Andrew J.
Rule, Andrew D.
Atwell, Thomas D.
Lerman, Lilach O.
Chen, Shigao
Huang, Chengwu
contents Objective: Hyper-clutter artifacts (HCA), arising from strong tissue reflections or physiological motion, present persistent challenges in ultrafast ultrasound Doppler imaging, often obscuring surrounding small vessel flow signals, especially in fascial regions such as the renal capsule. This study proposes U-profile-based decluttering (UPBD), a robust and computationally efficient method that exploits singular value decomposition (SVD)-derived spatial singular vectors to suppress HCA in ultrafast Doppler imaging. Methods: UPBD analyzes intensity profile of each pixel along the singular-order dimension of the SVD-derived left singular vectors U. A pixel-wise clutter-energy ratio is computed to derive a spatially adaptive declutter weighting map, which is applied to the SVD-filtered flow signals. Results: UPBD was evaluated on multiple in vivo datasets. Quantitative assessments based on contrast-to-noise ratio (CNR) and contrast-to-tissue ratio (CTR) demonstrated significant improvements over conventional SVD filtering. For example, UPBD enhanced CTR from 7.3 dB to 21.7 dB in contrast-free pig kidney, 17.8 dB to 42.1 dB in contrast-enhanced pig kidney, 8.2 dB to 32.8 dB in human kidney, and -4.9 dB to 3.7 dB in 3D human liver. Conclusion: The proposed UPBD method effectively suppresses HCA while preserving blood flow signals with minimal extra computational cost and no need for extensive parameter tuning. Significance: UPBD serves as a lightweight, easily integrated post-processing method that enhances HCA suppression, enabling broader application of SVD-based ultrafast Doppler imaging.
format Preprint
id arxiv_https___arxiv_org_abs_2511_21833
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging
Huang, Lijie
Yin, Jingyi
Zhang, Jingke
Lok, U-Wai
DeRuiter, Ryan M.
Ji, Kaipeng
Zhao, Yanzhe
Wu, Tao
Krier, James D.
Zhu, Xiang-yang
Bentall, Andrew J.
Rule, Andrew D.
Atwell, Thomas D.
Lerman, Lilach O.
Chen, Shigao
Huang, Chengwu
Medical Physics
Signal Processing
Objective: Hyper-clutter artifacts (HCA), arising from strong tissue reflections or physiological motion, present persistent challenges in ultrafast ultrasound Doppler imaging, often obscuring surrounding small vessel flow signals, especially in fascial regions such as the renal capsule. This study proposes U-profile-based decluttering (UPBD), a robust and computationally efficient method that exploits singular value decomposition (SVD)-derived spatial singular vectors to suppress HCA in ultrafast Doppler imaging. Methods: UPBD analyzes intensity profile of each pixel along the singular-order dimension of the SVD-derived left singular vectors U. A pixel-wise clutter-energy ratio is computed to derive a spatially adaptive declutter weighting map, which is applied to the SVD-filtered flow signals. Results: UPBD was evaluated on multiple in vivo datasets. Quantitative assessments based on contrast-to-noise ratio (CNR) and contrast-to-tissue ratio (CTR) demonstrated significant improvements over conventional SVD filtering. For example, UPBD enhanced CTR from 7.3 dB to 21.7 dB in contrast-free pig kidney, 17.8 dB to 42.1 dB in contrast-enhanced pig kidney, 8.2 dB to 32.8 dB in human kidney, and -4.9 dB to 3.7 dB in 3D human liver. Conclusion: The proposed UPBD method effectively suppresses HCA while preserving blood flow signals with minimal extra computational cost and no need for extensive parameter tuning. Significance: UPBD serves as a lightweight, easily integrated post-processing method that enhances HCA suppression, enabling broader application of SVD-based ultrafast Doppler imaging.
title Effective Hyper-clutter Artifacts Suppression for Ultrafast Ultrasound Doppler Imaging
topic Medical Physics
Signal Processing
url https://arxiv.org/abs/2511.21833