Design and Construction of a Dedicated Radiolucent 8-element Flexible Radiofrequency (RF) Torso Coil for the 1.0T Australian MRI-Linac System

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Li, Mingyan, Weber, Ewald, Waddington, David E. J., Shan, Shanshan, Liu, Paul, Dong, Bin, Keall, Paul J., Liu, Feng, Crozier, Stuart
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915643121467392
author Li, Mingyan
Weber, Ewald
Waddington, David E. J.
Shan, Shanshan
Liu, Paul
Dong, Bin
Keall, Paul J.
Liu, Feng
Crozier, Stuart
author_facet Li, Mingyan
Weber, Ewald
Waddington, David E. J.
Shan, Shanshan
Liu, Paul
Dong, Bin
Keall, Paul J.
Liu, Feng
Crozier, Stuart
contents Magnetic resonance imaging-guided linear accelerators (MRI-Linacs) are an emerging treatment technology that enable online soft-tissue visualisation and adaptive radiotherapy. The Australian 1.0 T MRI-Linac employs a fixed, inline beamline, with treatment angles achieved via patient couch rotation, and currently relies on a radiolucent whole-body radiofrequency (RF) coil. However, the large coil-patient separation limits signal-to-noise ratio (SNR) and constrains the fast imaging required for real-time tumour tracking. Here, we show the design and validation of a dedicated, flexible 8-element receive-only RF torso array tailored to the geometry and beam access requirements of the Australian MRI-Linac. Electromagnetic simulations, bench measurements, and phantom imaging demonstrate approximately three-fold SNR improvement at the centre and eight-fold improvement at superficial regions compared with the whole-body coil. In vivo abdominal imaging confirms enhanced anatomical detail and sharper tissue boundaries, and the increased SNR enables parallel imaging with GRAPPA acceleration factors up to three without severe artefacts. Dosimetry measurements and dynamic beam-on noise analysis confirm that the coil array is effectively radiolucent, with dose differences below 1% and no measurable degradation in image noise. This work demonstrates a practical RF solution for accelerated, high-SNR imaging compatible with patient rotation and beam delivery on the Australian MRI-Linac.
format Preprint
id arxiv_https___arxiv_org_abs_2511_22879
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Design and Construction of a Dedicated Radiolucent 8-element Flexible Radiofrequency (RF) Torso Coil for the 1.0T Australian MRI-Linac System
Li, Mingyan
Weber, Ewald
Waddington, David E. J.
Shan, Shanshan
Liu, Paul
Dong, Bin
Keall, Paul J.
Liu, Feng
Crozier, Stuart
Medical Physics
Magnetic resonance imaging-guided linear accelerators (MRI-Linacs) are an emerging treatment technology that enable online soft-tissue visualisation and adaptive radiotherapy. The Australian 1.0 T MRI-Linac employs a fixed, inline beamline, with treatment angles achieved via patient couch rotation, and currently relies on a radiolucent whole-body radiofrequency (RF) coil. However, the large coil-patient separation limits signal-to-noise ratio (SNR) and constrains the fast imaging required for real-time tumour tracking. Here, we show the design and validation of a dedicated, flexible 8-element receive-only RF torso array tailored to the geometry and beam access requirements of the Australian MRI-Linac. Electromagnetic simulations, bench measurements, and phantom imaging demonstrate approximately three-fold SNR improvement at the centre and eight-fold improvement at superficial regions compared with the whole-body coil. In vivo abdominal imaging confirms enhanced anatomical detail and sharper tissue boundaries, and the increased SNR enables parallel imaging with GRAPPA acceleration factors up to three without severe artefacts. Dosimetry measurements and dynamic beam-on noise analysis confirm that the coil array is effectively radiolucent, with dose differences below 1% and no measurable degradation in image noise. This work demonstrates a practical RF solution for accelerated, high-SNR imaging compatible with patient rotation and beam delivery on the Australian MRI-Linac.
title Design and Construction of a Dedicated Radiolucent 8-element Flexible Radiofrequency (RF) Torso Coil for the 1.0T Australian MRI-Linac System
topic Medical Physics
url https://arxiv.org/abs/2511.22879