Sleep Apnea Detection on a Wireless Multimodal Wearable Device Without Oxygen Flow Using a Mamba-based Deep Learning Approach

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Luszczynski, Dominik, Yin, Richard Fei, Afonin, Nicholas, Lim, Andrew S. P.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866909936981639168
author Luszczynski, Dominik
Yin, Richard Fei
Afonin, Nicholas
Lim, Andrew S. P.
author_facet Luszczynski, Dominik
Yin, Richard Fei
Afonin, Nicholas
Lim, Andrew S. P.
contents Objectives: We present and evaluate a Mamba-based deep-learning model for diagnosis and event-level characterization of sleep disordered breathing based on signals from the ANNE One, a non-intrusive dual-module wireless wearable system measuring chest electrocardiography, triaxial accelerometry, chest and finger temperature, and finger phototplethysmography. Methods: We obtained concurrent PSG and wearable sensor recordings from 384 adults attending a tertiary care sleep laboratory. Respiratory events in the PSG were manually annotated in accordance with AASM guidelines. Wearable sensor and PSG recordings were automatically aligned based on the ECG signal, alignment confirmed by visual inspection, and PSG-derived respiratory event labels were used to train and evaluate a deep sequential neural network based on the Mamba architecture. Results: In 57 recordings in our test set (mean age 56, mean AHI 10.8, 43.86\% female) the model-predicted AHI was highly correlated with that derived form the PSG labels (R=0.95, p=8.3e-30, men absolute error 2.83). This performance did not vary with age or sex. At a threshold of AHI$>$5, the model had a sensitivity of 0.96, specificity of 0.87, and kappa of 0.82, and at a threshold of AHI$>$15, the model had a sensitivity of 0.86, specificity of 0.98, and kappa of 0.85. At the level of 30-sec epochs, the model had a sensitivity of 0.93 and specificity of 0.95, with a kappa of 0.68 regarding whether any given epoch contained a respiratory event. Conclusions: Applied to data from the ANNE One, a Mamba-based deep learning model can accurately predict AHI and identify SDB at clinically relevant thresholds, achieves good epoch- and event-level identification of individual respiratory events, and shows promise at physiological characterization of these events including event type (central vs. other) and event duration.
format Preprint
id arxiv_https___arxiv_org_abs_2512_00989
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Sleep Apnea Detection on a Wireless Multimodal Wearable Device Without Oxygen Flow Using a Mamba-based Deep Learning Approach
Luszczynski, Dominik
Yin, Richard Fei
Afonin, Nicholas
Lim, Andrew S. P.
Quantitative Methods
Machine Learning
Objectives: We present and evaluate a Mamba-based deep-learning model for diagnosis and event-level characterization of sleep disordered breathing based on signals from the ANNE One, a non-intrusive dual-module wireless wearable system measuring chest electrocardiography, triaxial accelerometry, chest and finger temperature, and finger phototplethysmography. Methods: We obtained concurrent PSG and wearable sensor recordings from 384 adults attending a tertiary care sleep laboratory. Respiratory events in the PSG were manually annotated in accordance with AASM guidelines. Wearable sensor and PSG recordings were automatically aligned based on the ECG signal, alignment confirmed by visual inspection, and PSG-derived respiratory event labels were used to train and evaluate a deep sequential neural network based on the Mamba architecture. Results: In 57 recordings in our test set (mean age 56, mean AHI 10.8, 43.86\% female) the model-predicted AHI was highly correlated with that derived form the PSG labels (R=0.95, p=8.3e-30, men absolute error 2.83). This performance did not vary with age or sex. At a threshold of AHI$>$5, the model had a sensitivity of 0.96, specificity of 0.87, and kappa of 0.82, and at a threshold of AHI$>$15, the model had a sensitivity of 0.86, specificity of 0.98, and kappa of 0.85. At the level of 30-sec epochs, the model had a sensitivity of 0.93 and specificity of 0.95, with a kappa of 0.68 regarding whether any given epoch contained a respiratory event. Conclusions: Applied to data from the ANNE One, a Mamba-based deep learning model can accurately predict AHI and identify SDB at clinically relevant thresholds, achieves good epoch- and event-level identification of individual respiratory events, and shows promise at physiological characterization of these events including event type (central vs. other) and event duration.
title Sleep Apnea Detection on a Wireless Multimodal Wearable Device Without Oxygen Flow Using a Mamba-based Deep Learning Approach
topic Quantitative Methods
Machine Learning
url https://arxiv.org/abs/2512.00989