Sub-second A-scan Acquisition Using Marginal Spectral-Domain Quantum Optical Coherence Tomography

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Yepiz-Graciano, P. D., Salamanca-Roldán, D., Cruz-Ramírez, H., U'Ren, A. B., Ramírez-Alarcón, R.
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866918280685420544
author Yepiz-Graciano, P. D.
Salamanca-Roldán, D.
Cruz-Ramírez, H.
U'Ren, A. B.
Ramírez-Alarcón, R.
author_facet Yepiz-Graciano, P. D.
Salamanca-Roldán, D.
Cruz-Ramírez, H.
U'Ren, A. B.
Ramírez-Alarcón, R.
contents We report an optimized implementation of spectral-domain quantum optical coherence tomography (SD-QOCT) capable of acquiring axial scans (A-scans) of multilayer samples without in the absence of mechanical scanning, at an unprecedented speed. We demonstrate a proof-of-concept system that integrates a diffraction grating, a high-resolution intensified CCD camera, and a high-flux photon-pair source operating in the VIS-NIR region (810 nm). This configuration enables the acquisition of an entire marginal SD-QOCT interferogram in a single camera exposure, yielding a transverse A-scan with a record acquisition time of 100 ms and a penetration depth of 4 mm. The measured interferometric response shows excellent agreement with the theoretical model. These results represent a decisive step toward the practical deployment of SD-QOCT as a competitive imaging modality for biomedical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2512_01110
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Sub-second A-scan Acquisition Using Marginal Spectral-Domain Quantum Optical Coherence Tomography
Yepiz-Graciano, P. D.
Salamanca-Roldán, D.
Cruz-Ramírez, H.
U'Ren, A. B.
Ramírez-Alarcón, R.
Optics
Biological Physics
We report an optimized implementation of spectral-domain quantum optical coherence tomography (SD-QOCT) capable of acquiring axial scans (A-scans) of multilayer samples without in the absence of mechanical scanning, at an unprecedented speed. We demonstrate a proof-of-concept system that integrates a diffraction grating, a high-resolution intensified CCD camera, and a high-flux photon-pair source operating in the VIS-NIR region (810 nm). This configuration enables the acquisition of an entire marginal SD-QOCT interferogram in a single camera exposure, yielding a transverse A-scan with a record acquisition time of 100 ms and a penetration depth of 4 mm. The measured interferometric response shows excellent agreement with the theoretical model. These results represent a decisive step toward the practical deployment of SD-QOCT as a competitive imaging modality for biomedical applications.
title Sub-second A-scan Acquisition Using Marginal Spectral-Domain Quantum Optical Coherence Tomography
topic Optics
Biological Physics
url https://arxiv.org/abs/2512.01110