An Open-Path Eddy-Covariance Laser Spectrometer for Simultaneous Monitoring of CO$_2$, CH$_4$, and H$_2$O

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Meshcherinov, Viacheslav, Gazizov, Iskander, Pravuk, Bogdan, Kazakov, Viktor, Zenevich, Sergei, Spiridonov, Maxim, Gazizov, Shamil, Suvorov, Gennady, Kuricheva, Olga, Lebedev, Yuri, Vinogradov, Imant, Rodin, Alexander
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866917193731538944
author Meshcherinov, Viacheslav
Gazizov, Iskander
Pravuk, Bogdan
Kazakov, Viktor
Zenevich, Sergei
Spiridonov, Maxim
Gazizov, Shamil
Suvorov, Gennady
Kuricheva, Olga
Lebedev, Yuri
Vinogradov, Imant
Rodin, Alexander
author_facet Meshcherinov, Viacheslav
Gazizov, Iskander
Pravuk, Bogdan
Kazakov, Viktor
Zenevich, Sergei
Spiridonov, Maxim
Gazizov, Shamil
Suvorov, Gennady
Kuricheva, Olga
Lebedev, Yuri
Vinogradov, Imant
Rodin, Alexander
contents We present E-CAHORS $-$ a compact mid-infrared open-path diode-laser spectrometer designed for the simultaneous measurement of carbon dioxide, methane, and water vapor concentrations in the near-surface atmospheric layer. These measurements, combined with simultaneous data from a three-dimensional anemometer, can be used to determine fluxes using the eddy-covariance method. The instrument utilizes two interband cascade lasers operating at 2.78 $μ$m and 3.24 $μ$m within a novel four-pass M-shaped optical cell, which provides high signal power and long-term field operation without requiring active air sampling. Two detection techniques $-$ tunable diode laser absorption spectroscopy (TDLAS) and a simplified wavelength modulation spectroscopy (sWMS) $-$ were implemented and evaluated. Laboratory calibration demonstrated linear responses for all gases (R$^2$ $\approx$ 0.999) and detection precisions at 10 Hz of 311 ppb for CO$_2$, 8.87 ppb for CH$_4$, and 788 ppb for H$_2$O. Field tests conducted at a grassland site near Moscow showed strong correlations (R = 0.91 for CO$_2$ and H$_2$O, R = 0.67 for CH$_4$) with commercial LI-COR LI-7200 and LI-7700 analyzers. The TDLAS mode demonstrated lower noise and greater stability under outdoor conditions, while sWMS provided baseline-free spectra but was more sensitive to power fluctuations. E-CAHORS combines high precision, multi-species sensing capability with low power consumption (10 W) and a compact design (4.2 kg).
format Preprint
id arxiv_https___arxiv_org_abs_2512_01619
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle An Open-Path Eddy-Covariance Laser Spectrometer for Simultaneous Monitoring of CO$_2$, CH$_4$, and H$_2$O
Meshcherinov, Viacheslav
Gazizov, Iskander
Pravuk, Bogdan
Kazakov, Viktor
Zenevich, Sergei
Spiridonov, Maxim
Gazizov, Shamil
Suvorov, Gennady
Kuricheva, Olga
Lebedev, Yuri
Vinogradov, Imant
Rodin, Alexander
Instrumentation and Detectors
Applied Physics
We present E-CAHORS $-$ a compact mid-infrared open-path diode-laser spectrometer designed for the simultaneous measurement of carbon dioxide, methane, and water vapor concentrations in the near-surface atmospheric layer. These measurements, combined with simultaneous data from a three-dimensional anemometer, can be used to determine fluxes using the eddy-covariance method. The instrument utilizes two interband cascade lasers operating at 2.78 $μ$m and 3.24 $μ$m within a novel four-pass M-shaped optical cell, which provides high signal power and long-term field operation without requiring active air sampling. Two detection techniques $-$ tunable diode laser absorption spectroscopy (TDLAS) and a simplified wavelength modulation spectroscopy (sWMS) $-$ were implemented and evaluated. Laboratory calibration demonstrated linear responses for all gases (R$^2$ $\approx$ 0.999) and detection precisions at 10 Hz of 311 ppb for CO$_2$, 8.87 ppb for CH$_4$, and 788 ppb for H$_2$O. Field tests conducted at a grassland site near Moscow showed strong correlations (R = 0.91 for CO$_2$ and H$_2$O, R = 0.67 for CH$_4$) with commercial LI-COR LI-7200 and LI-7700 analyzers. The TDLAS mode demonstrated lower noise and greater stability under outdoor conditions, while sWMS provided baseline-free spectra but was more sensitive to power fluctuations. E-CAHORS combines high precision, multi-species sensing capability with low power consumption (10 W) and a compact design (4.2 kg).
title An Open-Path Eddy-Covariance Laser Spectrometer for Simultaneous Monitoring of CO$_2$, CH$_4$, and H$_2$O
topic Instrumentation and Detectors
Applied Physics
url https://arxiv.org/abs/2512.01619