Characterisation of the LAPPD, a large area microchannel-plate PMT

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Korpar, S., Dolenec, R., Grijalva, F., Lozar, A., Kodrič, A., Križan, P., Parashari, S., Pestotnik, R., Seljak, A., Žontar, D.
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866909940422017024
author Korpar, S.
Dolenec, R.
Grijalva, F.
Lozar, A.
Kodrič, A.
Križan, P.
Parashari, S.
Pestotnik, R.
Seljak, A.
Žontar, D.
author_facet Korpar, S.
Dolenec, R.
Grijalva, F.
Lozar, A.
Kodrič, A.
Križan, P.
Parashari, S.
Pestotnik, R.
Seljak, A.
Žontar, D.
contents We present a comprehensive characterization of the LAPPD Gen-II, a large-area microchannel-plate photomultiplier tube (MCP-PMT) equipped with a capacitively coupled sensing (readout) electrode. Two detector variants with different geometries and materials were investigated using a picosecond pulsed laser system. We measured the single-photon timing response and spatial charge distribution on segmented readout electrodes. The prompt timing peak exhibits a resolution of approximately 30 ps, with the overall timing structure explained by photoelectron propagation and back-scattering effects from the MCP input surface. We developed analytical models that describe the propagation of photoelectrons and the induced charge spread on the sensing electrodes, including secondary electron backscattering from the resistive anode. The model accurately reproduces the measured device properties and enables performance extrapolations for various detector geometries and dielectric properties. These results provide a predictive framework for optimizing MCP-PMTs for timing- and imaging-critical applications such as RICH detectors in high-energy physics and TOF-PET systems for medical imaging.
format Preprint
id arxiv_https___arxiv_org_abs_2512_02990
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Characterisation of the LAPPD, a large area microchannel-plate PMT
Korpar, S.
Dolenec, R.
Grijalva, F.
Lozar, A.
Kodrič, A.
Križan, P.
Parashari, S.
Pestotnik, R.
Seljak, A.
Žontar, D.
Instrumentation and Detectors
We present a comprehensive characterization of the LAPPD Gen-II, a large-area microchannel-plate photomultiplier tube (MCP-PMT) equipped with a capacitively coupled sensing (readout) electrode. Two detector variants with different geometries and materials were investigated using a picosecond pulsed laser system. We measured the single-photon timing response and spatial charge distribution on segmented readout electrodes. The prompt timing peak exhibits a resolution of approximately 30 ps, with the overall timing structure explained by photoelectron propagation and back-scattering effects from the MCP input surface. We developed analytical models that describe the propagation of photoelectrons and the induced charge spread on the sensing electrodes, including secondary electron backscattering from the resistive anode. The model accurately reproduces the measured device properties and enables performance extrapolations for various detector geometries and dielectric properties. These results provide a predictive framework for optimizing MCP-PMTs for timing- and imaging-critical applications such as RICH detectors in high-energy physics and TOF-PET systems for medical imaging.
title Characterisation of the LAPPD, a large area microchannel-plate PMT
topic Instrumentation and Detectors
url https://arxiv.org/abs/2512.02990