Mu2e Straw Tube Tracker Gas Flow Quality Control

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Bharatwaj, Vishal, Israel, Scott N., Jangra, Mamta, Nguyen, Minh Truong, Peck, Joey, Stortini, Matthew, Tran, Nam H., Ambrose, Dan, Edmonds, Andrew, Hass, Hannah, Martin, Emma R., Mukherjee, Aseet, Northrup, Klara, Popp, James L., Rusu, Vadim L., Tschirhart, Robert S., Wagner, Robert L.
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911602040635392
author Bharatwaj, Vishal
Israel, Scott N.
Jangra, Mamta
Nguyen, Minh Truong
Peck, Joey
Stortini, Matthew
Tran, Nam H.
Ambrose, Dan
Edmonds, Andrew
Hass, Hannah
Martin, Emma R.
Mukherjee, Aseet
Northrup, Klara
Popp, James L.
Rusu, Vadim L.
Tschirhart, Robert S.
Wagner, Robert L.
author_facet Bharatwaj, Vishal
Israel, Scott N.
Jangra, Mamta
Nguyen, Minh Truong
Peck, Joey
Stortini, Matthew
Tran, Nam H.
Ambrose, Dan
Edmonds, Andrew
Hass, Hannah
Martin, Emma R.
Mukherjee, Aseet
Northrup, Klara
Popp, James L.
Rusu, Vadim L.
Tschirhart, Robert S.
Wagner, Robert L.
contents We present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55Fe source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening.
format Preprint
id arxiv_https___arxiv_org_abs_2512_04286
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Mu2e Straw Tube Tracker Gas Flow Quality Control
Bharatwaj, Vishal
Israel, Scott N.
Jangra, Mamta
Nguyen, Minh Truong
Peck, Joey
Stortini, Matthew
Tran, Nam H.
Ambrose, Dan
Edmonds, Andrew
Hass, Hannah
Martin, Emma R.
Mukherjee, Aseet
Northrup, Klara
Popp, James L.
Rusu, Vadim L.
Tschirhart, Robert S.
Wagner, Robert L.
Instrumentation and Detectors
High Energy Physics - Experiment
We present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55Fe source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening.
title Mu2e Straw Tube Tracker Gas Flow Quality Control
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2512.04286