Mu2e Straw Tube Tracker Gas Flow Quality Control
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2025
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866911602040635392 |
|---|---|
| author | Bharatwaj, Vishal Israel, Scott N. Jangra, Mamta Nguyen, Minh Truong Peck, Joey Stortini, Matthew Tran, Nam H. Ambrose, Dan Edmonds, Andrew Hass, Hannah Martin, Emma R. Mukherjee, Aseet Northrup, Klara Popp, James L. Rusu, Vadim L. Tschirhart, Robert S. Wagner, Robert L. |
| author_facet | Bharatwaj, Vishal Israel, Scott N. Jangra, Mamta Nguyen, Minh Truong Peck, Joey Stortini, Matthew Tran, Nam H. Ambrose, Dan Edmonds, Andrew Hass, Hannah Martin, Emma R. Mukherjee, Aseet Northrup, Klara Popp, James L. Rusu, Vadim L. Tschirhart, Robert S. Wagner, Robert L. |
| contents | We present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55Fe source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2512_04286 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Mu2e Straw Tube Tracker Gas Flow Quality Control Bharatwaj, Vishal Israel, Scott N. Jangra, Mamta Nguyen, Minh Truong Peck, Joey Stortini, Matthew Tran, Nam H. Ambrose, Dan Edmonds, Andrew Hass, Hannah Martin, Emma R. Mukherjee, Aseet Northrup, Klara Popp, James L. Rusu, Vadim L. Tschirhart, Robert S. Wagner, Robert L. Instrumentation and Detectors High Energy Physics - Experiment We present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55Fe source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening. |
| title | Mu2e Straw Tube Tracker Gas Flow Quality Control |
| topic | Instrumentation and Detectors High Energy Physics - Experiment |
| url | https://arxiv.org/abs/2512.04286 |