Development & first Performance evaluation of multi-element monolithic HPGe detector for X-ray spectroscopy
Fuente:
arXiv
Saved in:
| Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Published: |
2025
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1866912770444754944 |
|---|---|
| author | Goyal, N. Iguaz, F. J. Aplin, S. Balerna, A. Bell, P. Casas, J. Cascella, M. Chatterji, S. Cohen, C. Collet, E. Gimenez, E. N. Graafsma, H. Hirsemann, H. Klementiev, K. Kolodziej, T. Martin, T. Menk, R. H. Menneglier, C. Meraihia, C. Murias, J. R. Porro, M. Quispe, M. Schmitt, B. Scully, S. Turcato, M. Ward, C. Welter, E. |
| author_facet | Goyal, N. Iguaz, F. J. Aplin, S. Balerna, A. Bell, P. Casas, J. Cascella, M. Chatterji, S. Cohen, C. Collet, E. Gimenez, E. N. Graafsma, H. Hirsemann, H. Klementiev, K. Kolodziej, T. Martin, T. Menk, R. H. Menneglier, C. Meraihia, C. Murias, J. R. Porro, M. Quispe, M. Schmitt, B. Scully, S. Turcato, M. Ward, C. Welter, E. |
| contents | The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution X-ray spectroscopy in the hard X-ray regime, capable of handling high count rates (20-250 kcps/mm2) across a broad energy range (5-100 keV). We discuss here a complete laboratory-based characterization of the detector's performance, as well as an on-beam evaluation at the BM05 beamline of the ESRF synchrotron facility, using monochromatic X-rays in the 20-50 keV energy range. We provide a detailed performance assessment that also includes a phenomenological defect-depth estimation model. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2512_08389 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Development & first Performance evaluation of multi-element monolithic HPGe detector for X-ray spectroscopy Goyal, N. Iguaz, F. J. Aplin, S. Balerna, A. Bell, P. Casas, J. Cascella, M. Chatterji, S. Cohen, C. Collet, E. Gimenez, E. N. Graafsma, H. Hirsemann, H. Klementiev, K. Kolodziej, T. Martin, T. Menk, R. H. Menneglier, C. Meraihia, C. Murias, J. R. Porro, M. Quispe, M. Schmitt, B. Scully, S. Turcato, M. Ward, C. Welter, E. Instrumentation and Detectors The first operational prototype of a high-purity Germanium (HPGe) detector developed within the European LEAPS-INNOV project is presented in this work. This prototype features a monolithic, multi-element sensor optimized for high-resolution X-ray spectroscopy in the hard X-ray regime, capable of handling high count rates (20-250 kcps/mm2) across a broad energy range (5-100 keV). We discuss here a complete laboratory-based characterization of the detector's performance, as well as an on-beam evaluation at the BM05 beamline of the ESRF synchrotron facility, using monochromatic X-rays in the 20-50 keV energy range. We provide a detailed performance assessment that also includes a phenomenological defect-depth estimation model. |
| title | Development & first Performance evaluation of multi-element monolithic HPGe detector for X-ray spectroscopy |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2512.08389 |