Atomic and molecular systems for radiation thermometry

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Eckel, Stephen P., Norrgard, Eric B., Holloway, Christopher, Prajapati, Nikunjkumar, Schlossberger, Noah, Simons, Matthew
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911681338146816
author Eckel, Stephen P.
Norrgard, Eric B.
Holloway, Christopher
Prajapati, Nikunjkumar
Schlossberger, Noah
Simons, Matthew
author_facet Eckel, Stephen P.
Norrgard, Eric B.
Holloway, Christopher
Prajapati, Nikunjkumar
Schlossberger, Noah
Simons, Matthew
contents Atoms and simple molecules are excellent candidates for new standards and sensors because they are both all identical and their properties are determined by the immutable laws of quantum physics. Here, we introduce the concept of building a standard and sensor of radiative temperature using atoms and molecules. Such standards are based on precise measurement of the rate at which blackbody radiation (BBR) either excites or stimulates emission for a given atomic transition. We summarize the recent results of two experiments while detailing the rate equation models required for their interpretation. The cold atom thermometer (CAT) uses a gas of laser cooled $^{85}$Rb Rydberg atoms to probe the BBR spectrum near 130~GHz. This primary, {\it i.e.}, not traceable to a measurement of like kind, temperature measurement currently has a total uncertainty of approximately 1~\%, with clear paths toward improvement. The compact blackbody radiation atomic sensor (CoBRAS) uses a vapour of $^{85}$Rb and monitors fluorescence from states that are either populated by BBR or populated by spontaneous emission to measure the blackbody spectrum near 24.5~THz. The CoBRAS has an excellent relative precision of $u(T)\approx 0.13$~K, with a clear path toward implementing a primary
format Preprint
id arxiv_https___arxiv_org_abs_2512_08668
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Atomic and molecular systems for radiation thermometry
Eckel, Stephen P.
Norrgard, Eric B.
Holloway, Christopher
Prajapati, Nikunjkumar
Schlossberger, Noah
Simons, Matthew
Atomic Physics
Atoms and simple molecules are excellent candidates for new standards and sensors because they are both all identical and their properties are determined by the immutable laws of quantum physics. Here, we introduce the concept of building a standard and sensor of radiative temperature using atoms and molecules. Such standards are based on precise measurement of the rate at which blackbody radiation (BBR) either excites or stimulates emission for a given atomic transition. We summarize the recent results of two experiments while detailing the rate equation models required for their interpretation. The cold atom thermometer (CAT) uses a gas of laser cooled $^{85}$Rb Rydberg atoms to probe the BBR spectrum near 130~GHz. This primary, {\it i.e.}, not traceable to a measurement of like kind, temperature measurement currently has a total uncertainty of approximately 1~\%, with clear paths toward improvement. The compact blackbody radiation atomic sensor (CoBRAS) uses a vapour of $^{85}$Rb and monitors fluorescence from states that are either populated by BBR or populated by spontaneous emission to measure the blackbody spectrum near 24.5~THz. The CoBRAS has an excellent relative precision of $u(T)\approx 0.13$~K, with a clear path toward implementing a primary
title Atomic and molecular systems for radiation thermometry
topic Atomic Physics
url https://arxiv.org/abs/2512.08668