_version_ 1866917135783034880
author Barresi, A.
Chiesa, D.
Merli, D.
Nastasi, M.
Nisi, S.
Previtali, E.
Sisti, M.
Borghesi, M.
Cammi, A.
Coletta, C.
Ferrante, G.
Loi, L.
Andronico, G.
Antonelli, V.
Basilico, D.
Beretta, M.
Bergnoli, A.
Brigatti, A.
Brugnera, R.
Bruno, R.
Budano, A.
Caccianiga, B.
Cerrone, V.
Caruso, R.
Clementi, C.
D'Auria, L. V.
Dusini, S.
Fabbri, A.
Felici, G.
Garfagnini, A.
Giammarchi, M. G.
Giudice, N.
Gavrikov, A.
Grassi, M.
Guardone, N.
Houria, F.
Landini, C.
Lastrucci, L.
Lippi, I.
Lombardi, P.
Mantovani, F.
Mari, S. M.
Martini, A.
Miramonti, L.
Montuschi, M.
Orestano, D.
Ortica, F.
Paoloni, A.
Pelicci, L.
Percalli, E.
Petrucci, F.
Ranucci, G.
Re, A. C.
Ricci, B.
Romani, A.
Saggese, P.
Serafini, A.
Sirignano, C.
Stanco, L.
Farilla, E. Stanescu
Strati, V.
Torri, M. D. C
Tuve', C.
Venettacci, C.
Verde, G.
Votano, L.
author_facet Barresi, A.
Chiesa, D.
Merli, D.
Nastasi, M.
Nisi, S.
Previtali, E.
Sisti, M.
Borghesi, M.
Cammi, A.
Coletta, C.
Ferrante, G.
Loi, L.
Andronico, G.
Antonelli, V.
Basilico, D.
Beretta, M.
Bergnoli, A.
Brigatti, A.
Brugnera, R.
Bruno, R.
Budano, A.
Caccianiga, B.
Cerrone, V.
Caruso, R.
Clementi, C.
D'Auria, L. V.
Dusini, S.
Fabbri, A.
Felici, G.
Garfagnini, A.
Giammarchi, M. G.
Giudice, N.
Gavrikov, A.
Grassi, M.
Guardone, N.
Houria, F.
Landini, C.
Lastrucci, L.
Lippi, I.
Lombardi, P.
Mantovani, F.
Mari, S. M.
Martini, A.
Miramonti, L.
Montuschi, M.
Orestano, D.
Ortica, F.
Paoloni, A.
Pelicci, L.
Percalli, E.
Petrucci, F.
Ranucci, G.
Re, A. C.
Ricci, B.
Romani, A.
Saggese, P.
Serafini, A.
Sirignano, C.
Stanco, L.
Farilla, E. Stanescu
Strati, V.
Torri, M. D. C
Tuve', C.
Venettacci, C.
Verde, G.
Votano, L.
contents Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants -- $^{238}$U and $^{232}$Th -- with sensitivities at the \qty{E-15}{g/g} level. Our method combines neutron activation analysis with radiochemical techniques, followed by \bg\ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of \qty{0.65E-15}{g/g} for $^{238}$U and \qty{2.3E-15}{g/g} for $^{232}$Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions.
format Preprint
id arxiv_https___arxiv_org_abs_2512_08988
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Ultra-trace analysis of U and Th in organic liquid scintillators with high sensitivity
Barresi, A.
Chiesa, D.
Merli, D.
Nastasi, M.
Nisi, S.
Previtali, E.
Sisti, M.
Borghesi, M.
Cammi, A.
Coletta, C.
Ferrante, G.
Loi, L.
Andronico, G.
Antonelli, V.
Basilico, D.
Beretta, M.
Bergnoli, A.
Brigatti, A.
Brugnera, R.
Bruno, R.
Budano, A.
Caccianiga, B.
Cerrone, V.
Caruso, R.
Clementi, C.
D'Auria, L. V.
Dusini, S.
Fabbri, A.
Felici, G.
Garfagnini, A.
Giammarchi, M. G.
Giudice, N.
Gavrikov, A.
Grassi, M.
Guardone, N.
Houria, F.
Landini, C.
Lastrucci, L.
Lippi, I.
Lombardi, P.
Mantovani, F.
Mari, S. M.
Martini, A.
Miramonti, L.
Montuschi, M.
Orestano, D.
Ortica, F.
Paoloni, A.
Pelicci, L.
Percalli, E.
Petrucci, F.
Ranucci, G.
Re, A. C.
Ricci, B.
Romani, A.
Saggese, P.
Serafini, A.
Sirignano, C.
Stanco, L.
Farilla, E. Stanescu
Strati, V.
Torri, M. D. C
Tuve', C.
Venettacci, C.
Verde, G.
Votano, L.
Instrumentation and Detectors
Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants -- $^{238}$U and $^{232}$Th -- with sensitivities at the \qty{E-15}{g/g} level. Our method combines neutron activation analysis with radiochemical techniques, followed by \bg\ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of \qty{0.65E-15}{g/g} for $^{238}$U and \qty{2.3E-15}{g/g} for $^{232}$Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions.
title Ultra-trace analysis of U and Th in organic liquid scintillators with high sensitivity
topic Instrumentation and Detectors
url https://arxiv.org/abs/2512.08988