Freely controllable single-optical-frequency comb for highly sensitive cavity ring-down spectroscopy

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Nishizawa, Norihiko, Kitajima, Shotaro, Liu, Ningwu, Terabayashi, Ryohei, Hashimoto, Daiki, Abe, Hisashi, Tomita, Hideki
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866917135867969536
author Nishizawa, Norihiko
Kitajima, Shotaro
Liu, Ningwu
Terabayashi, Ryohei
Hashimoto, Daiki
Abe, Hisashi
Tomita, Hideki
author_facet Nishizawa, Norihiko
Kitajima, Shotaro
Liu, Ningwu
Terabayashi, Ryohei
Hashimoto, Daiki
Abe, Hisashi
Tomita, Hideki
contents Direct comb spectroscopy is a useful tool for obtaining highly accurate spectroscopic information. However, as the number of comb modes is very large and the optical energy is dispersed over them, the optical energy per each comb mode is ultrasmall, limiting the sensitivity of highly sensitive spectroscopy. If we can concentrate the optical energy into the comb modes that only overlap with the absorption spectra, we can demonstrate drastic improvements in its measurement sensitivity. In this study, we developed a freely controllable optical frequency comb source based on the spectral peak phenomenon. The comb modes overlapping the CH4 absorption spectra were transformed into background-suppressed spectral peaks at the nonlinear loop mirror using a CH4 gas cell. Coherence-preserving power scaling of the generated comb was demonstrated using a fiber Raman amplifier. Subsequently, only the single-comb mode was filtered using a newly developed spectral filter with an ultrahigh resolution. The maximum optical power of a single comb was estimated to be more than 10 mW. The ring-down decay signal from the high-finesse optical cavity was measured using a single selected mode of the generated controllable comb. As a demonstration, the 2v_3 bands of the CH4 absorption spectra were accurately measured by comb-mode-resolved, cavity ring-down spectroscopy (CRDS) with high sensitivity up to 4.2 x 10^(-11) cm^(-1). This sensitivity is two orders of magnitude higher than that of previously reported comb-based CRDS. The residual was only 0.29 %, indicating the high accuracy of the proposed spectrometer for molecular spectral analysis. This approach can be extended to other wavelength ranges and is useful for highly sensitive, high-resolution, comb-resolved spectroscopy.
format Preprint
id arxiv_https___arxiv_org_abs_2512_09159
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Freely controllable single-optical-frequency comb for highly sensitive cavity ring-down spectroscopy
Nishizawa, Norihiko
Kitajima, Shotaro
Liu, Ningwu
Terabayashi, Ryohei
Hashimoto, Daiki
Abe, Hisashi
Tomita, Hideki
Optics
Direct comb spectroscopy is a useful tool for obtaining highly accurate spectroscopic information. However, as the number of comb modes is very large and the optical energy is dispersed over them, the optical energy per each comb mode is ultrasmall, limiting the sensitivity of highly sensitive spectroscopy. If we can concentrate the optical energy into the comb modes that only overlap with the absorption spectra, we can demonstrate drastic improvements in its measurement sensitivity. In this study, we developed a freely controllable optical frequency comb source based on the spectral peak phenomenon. The comb modes overlapping the CH4 absorption spectra were transformed into background-suppressed spectral peaks at the nonlinear loop mirror using a CH4 gas cell. Coherence-preserving power scaling of the generated comb was demonstrated using a fiber Raman amplifier. Subsequently, only the single-comb mode was filtered using a newly developed spectral filter with an ultrahigh resolution. The maximum optical power of a single comb was estimated to be more than 10 mW. The ring-down decay signal from the high-finesse optical cavity was measured using a single selected mode of the generated controllable comb. As a demonstration, the 2v_3 bands of the CH4 absorption spectra were accurately measured by comb-mode-resolved, cavity ring-down spectroscopy (CRDS) with high sensitivity up to 4.2 x 10^(-11) cm^(-1). This sensitivity is two orders of magnitude higher than that of previously reported comb-based CRDS. The residual was only 0.29 %, indicating the high accuracy of the proposed spectrometer for molecular spectral analysis. This approach can be extended to other wavelength ranges and is useful for highly sensitive, high-resolution, comb-resolved spectroscopy.
title Freely controllable single-optical-frequency comb for highly sensitive cavity ring-down spectroscopy
topic Optics
url https://arxiv.org/abs/2512.09159