Accurate laboratory testing of low-frequency triaxial vibration sensors under various environmental conditions

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Shimoda, Tomofumi, Kokuyama, Wataru, Nozato, Hideaki
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914195341049856
author Shimoda, Tomofumi
Kokuyama, Wataru
Nozato, Hideaki
author_facet Shimoda, Tomofumi
Kokuyama, Wataru
Nozato, Hideaki
contents Triaxial vibration sensor are widely used used in various application. Recently, low-cost sensors based on micro electro mechanical system (MEMS) technology are also becoming more widely adopted. However, their measurement accuracy can be affected by environmental factors such as temperature. In this study, we developed an environmental testing system integrated with a triaxial vibration exciter. The system can reproduce long-stroke, low-frequency triaxial vibrations -- such as those caused by huge earthquakes -- under temperatures ranging from $-30~^\circ\mathrm{C}$ to $+80~^\circ\mathrm{C}$. Using this system, the measurement accuracy of vibration sensors can be evaluated under different environmental conditions. The system provides highly accurate reference measurements using a laser interferometer and reference accelerometers that are primarily calibrated within the system. The overall accuracy of the reference vibration measurement is estimated to be approximately 0.23~\%. Based on these reference measurements, we investigated the accuracy of earthquake observations using a MEMS accelerometer as a demonstration. The system configuration and testing procedures are presented in this paper.
format Preprint
id arxiv_https___arxiv_org_abs_2512_10771
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Accurate laboratory testing of low-frequency triaxial vibration sensors under various environmental conditions
Shimoda, Tomofumi
Kokuyama, Wataru
Nozato, Hideaki
Instrumentation and Detectors
Triaxial vibration sensor are widely used used in various application. Recently, low-cost sensors based on micro electro mechanical system (MEMS) technology are also becoming more widely adopted. However, their measurement accuracy can be affected by environmental factors such as temperature. In this study, we developed an environmental testing system integrated with a triaxial vibration exciter. The system can reproduce long-stroke, low-frequency triaxial vibrations -- such as those caused by huge earthquakes -- under temperatures ranging from $-30~^\circ\mathrm{C}$ to $+80~^\circ\mathrm{C}$. Using this system, the measurement accuracy of vibration sensors can be evaluated under different environmental conditions. The system provides highly accurate reference measurements using a laser interferometer and reference accelerometers that are primarily calibrated within the system. The overall accuracy of the reference vibration measurement is estimated to be approximately 0.23~\%. Based on these reference measurements, we investigated the accuracy of earthquake observations using a MEMS accelerometer as a demonstration. The system configuration and testing procedures are presented in this paper.
title Accurate laboratory testing of low-frequency triaxial vibration sensors under various environmental conditions
topic Instrumentation and Detectors
url https://arxiv.org/abs/2512.10771