DBT-DINO: Towards Foundation model based analysis of Digital Breast Tomosynthesis

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Dorfner, Felix J., Dorster, Manon A., Connolly, Ryan, Gentilhomme, Oscar, Gibbs, Edward, Graham, Steven, Wander, Seth, Schultz, Thomas, Bahl, Manisha, Daye, Dania, Kim, Albert E., Bridge, Christopher P.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918249187246080
author Dorfner, Felix J.
Dorster, Manon A.
Connolly, Ryan
Gentilhomme, Oscar
Gibbs, Edward
Graham, Steven
Wander, Seth
Schultz, Thomas
Bahl, Manisha
Daye, Dania
Kim, Albert E.
Bridge, Christopher P.
author_facet Dorfner, Felix J.
Dorster, Manon A.
Connolly, Ryan
Gentilhomme, Oscar
Gibbs, Edward
Graham, Steven
Wander, Seth
Schultz, Thomas
Bahl, Manisha
Daye, Dania
Kim, Albert E.
Bridge, Christopher P.
contents Foundation models have shown promise in medical imaging but remain underexplored for three-dimensional imaging modalities. No foundation model currently exists for Digital Breast Tomosynthesis (DBT), despite its use for breast cancer screening. To develop and evaluate a foundation model for DBT (DBT-DINO) across multiple clinical tasks and assess the impact of domain-specific pre-training. Self-supervised pre-training was performed using the DINOv2 methodology on over 25 million 2D slices from 487,975 DBT volumes from 27,990 patients. Three downstream tasks were evaluated: (1) breast density classification using 5,000 screening exams; (2) 5-year risk of developing breast cancer using 106,417 screening exams; and (3) lesion detection using 393 annotated volumes. For breast density classification, DBT-DINO achieved an accuracy of 0.79 (95\% CI: 0.76--0.81), outperforming both the MetaAI DINOv2 baseline (0.73, 95\% CI: 0.70--0.76, p<.001) and DenseNet-121 (0.74, 95\% CI: 0.71--0.76, p<.001). For 5-year breast cancer risk prediction, DBT-DINO achieved an AUROC of 0.78 (95\% CI: 0.76--0.80) compared to DINOv2's 0.76 (95\% CI: 0.74--0.78, p=.57). For lesion detection, DINOv2 achieved a higher average sensitivity of 0.67 (95\% CI: 0.60--0.74) compared to DBT-DINO with 0.62 (95\% CI: 0.53--0.71, p=.60). DBT-DINO demonstrated better performance on cancerous lesions specifically with a detection rate of 78.8\% compared to Dinov2's 77.3\%. Using a dataset of unprecedented size, we developed DBT-DINO, the first foundation model for DBT. DBT-DINO demonstrated strong performance on breast density classification and cancer risk prediction. However, domain-specific pre-training showed variable benefits on the detection task, with ImageNet baseline outperforming DBT-DINO on general lesion detection, indicating that localized detection tasks require further methodological development.
format Preprint
id arxiv_https___arxiv_org_abs_2512_13608
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle DBT-DINO: Towards Foundation model based analysis of Digital Breast Tomosynthesis
Dorfner, Felix J.
Dorster, Manon A.
Connolly, Ryan
Gentilhomme, Oscar
Gibbs, Edward
Graham, Steven
Wander, Seth
Schultz, Thomas
Bahl, Manisha
Daye, Dania
Kim, Albert E.
Bridge, Christopher P.
Computer Vision and Pattern Recognition
Foundation models have shown promise in medical imaging but remain underexplored for three-dimensional imaging modalities. No foundation model currently exists for Digital Breast Tomosynthesis (DBT), despite its use for breast cancer screening. To develop and evaluate a foundation model for DBT (DBT-DINO) across multiple clinical tasks and assess the impact of domain-specific pre-training. Self-supervised pre-training was performed using the DINOv2 methodology on over 25 million 2D slices from 487,975 DBT volumes from 27,990 patients. Three downstream tasks were evaluated: (1) breast density classification using 5,000 screening exams; (2) 5-year risk of developing breast cancer using 106,417 screening exams; and (3) lesion detection using 393 annotated volumes. For breast density classification, DBT-DINO achieved an accuracy of 0.79 (95\% CI: 0.76--0.81), outperforming both the MetaAI DINOv2 baseline (0.73, 95\% CI: 0.70--0.76, p<.001) and DenseNet-121 (0.74, 95\% CI: 0.71--0.76, p<.001). For 5-year breast cancer risk prediction, DBT-DINO achieved an AUROC of 0.78 (95\% CI: 0.76--0.80) compared to DINOv2's 0.76 (95\% CI: 0.74--0.78, p=.57). For lesion detection, DINOv2 achieved a higher average sensitivity of 0.67 (95\% CI: 0.60--0.74) compared to DBT-DINO with 0.62 (95\% CI: 0.53--0.71, p=.60). DBT-DINO demonstrated better performance on cancerous lesions specifically with a detection rate of 78.8\% compared to Dinov2's 77.3\%. Using a dataset of unprecedented size, we developed DBT-DINO, the first foundation model for DBT. DBT-DINO demonstrated strong performance on breast density classification and cancer risk prediction. However, domain-specific pre-training showed variable benefits on the detection task, with ImageNet baseline outperforming DBT-DINO on general lesion detection, indicating that localized detection tasks require further methodological development.
title DBT-DINO: Towards Foundation model based analysis of Digital Breast Tomosynthesis
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2512.13608