AMKID -- a large KID-based camera at the APEX telescope

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Reyes, N., Weiss, A., Yates, S. J. C., Baryshev, A. M., mara-Mayorga, I. C., Endo, S. Dabironezare A., Ferrari, L., Görlitz, A., Grutzeck, G., Güsten, R., Heiter, C., Heyminck, S., Hochgürtel, S., Hoevers, H., Jorquera, S., Kovàcs, A., Koopmans, D., König, C., Llombart, N., Menten, K. M., Murugesan, V., Ridder, M., Schmitz, A., Thoen, D. J., van der Linden, A. J., Wang, L., Yurduseven, O., Baselmans, J. J. A., Klein, B.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866908910068170752
author Reyes, N.
Weiss, A.
Yates, S. J. C.
Baryshev, A. M.
mara-Mayorga, I. C.
Endo, S. Dabironezare A.
Ferrari, L.
Görlitz, A.
Grutzeck, G.
Güsten, R.
Heiter, C.
Heyminck, S.
Hochgürtel, S.
Hoevers, H.
Jorquera, S.
Kovàcs, A.
Koopmans, D.
König, C.
Llombart, N.
Menten, K. M.
Murugesan, V.
Ridder, M.
Schmitz, A.
Thoen, D. J.
van der Linden, A. J.
Wang, L.
Yurduseven, O.
Baselmans, J. J. A.
Klein, B.
author_facet Reyes, N.
Weiss, A.
Yates, S. J. C.
Baryshev, A. M.
mara-Mayorga, I. C.
Endo, S. Dabironezare A.
Ferrari, L.
Görlitz, A.
Grutzeck, G.
Güsten, R.
Heiter, C.
Heyminck, S.
Hochgürtel, S.
Hoevers, H.
Jorquera, S.
Kovàcs, A.
Koopmans, D.
König, C.
Llombart, N.
Menten, K. M.
Murugesan, V.
Ridder, M.
Schmitz, A.
Thoen, D. J.
van der Linden, A. J.
Wang, L.
Yurduseven, O.
Baselmans, J. J. A.
Klein, B.
contents The thermal emission at sub-millimeter wavelengths carries unique information in many astronomical applications ranging from disks and planet formation around young stars, to galaxy evolution studies at cosmological distances. Advancing on the mapping speed to detect this faint emission in ground-based astronomy has been a technical challenge for decades. The APEX Microwave Kinetic Inductance Detector (AMKID) camera was designed to accomplish this task. The instrument is a wide field-of-view camera based on kinetic inductance detectors. It is installed on the 12~meter APEX telescope in Chile at 5.100~meters above see level. The instrument operates dual color, covering simultaneously the 350~GHz and 850~GHz atmospheric windows. It has a large field-of-view of 15.3'x15.3', and an unprecedented number of pixels: 13.952~detectors in the high frequency band and 3.520~detectors in the low frequency band. Here we present a complete description of the instrument design and construction together with results of the successful low frequency array (LFA) commissioning campaign executed during the last year. The LFA performance is in good agreement with design parameters, with detector sensitivity of 2.2~mK$\sqrt{s}$ and diffraction limited beam sizes of 17.0''. On-sky measurements demonstrate a sensitivity of 70-90~mJy$\sqrt{s}$ per detector when operating under good atmospheric conditions (PWV below 1.0mm). With this performance the LFA regularly achieve a mapping sensitivity of 25~mJy when mapping a square degree in an hour. AMKID on APEX with its dual color observing capabilities, high sensitivity, large field-of-view and high angular resolution holds the promise to open a new range of science with the APEX telescope.
format Preprint
id arxiv_https___arxiv_org_abs_2512_14905
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle AMKID -- a large KID-based camera at the APEX telescope
Reyes, N.
Weiss, A.
Yates, S. J. C.
Baryshev, A. M.
mara-Mayorga, I. C.
Endo, S. Dabironezare A.
Ferrari, L.
Görlitz, A.
Grutzeck, G.
Güsten, R.
Heiter, C.
Heyminck, S.
Hochgürtel, S.
Hoevers, H.
Jorquera, S.
Kovàcs, A.
Koopmans, D.
König, C.
Llombart, N.
Menten, K. M.
Murugesan, V.
Ridder, M.
Schmitz, A.
Thoen, D. J.
van der Linden, A. J.
Wang, L.
Yurduseven, O.
Baselmans, J. J. A.
Klein, B.
Instrumentation and Methods for Astrophysics
The thermal emission at sub-millimeter wavelengths carries unique information in many astronomical applications ranging from disks and planet formation around young stars, to galaxy evolution studies at cosmological distances. Advancing on the mapping speed to detect this faint emission in ground-based astronomy has been a technical challenge for decades. The APEX Microwave Kinetic Inductance Detector (AMKID) camera was designed to accomplish this task. The instrument is a wide field-of-view camera based on kinetic inductance detectors. It is installed on the 12~meter APEX telescope in Chile at 5.100~meters above see level. The instrument operates dual color, covering simultaneously the 350~GHz and 850~GHz atmospheric windows. It has a large field-of-view of 15.3'x15.3', and an unprecedented number of pixels: 13.952~detectors in the high frequency band and 3.520~detectors in the low frequency band. Here we present a complete description of the instrument design and construction together with results of the successful low frequency array (LFA) commissioning campaign executed during the last year. The LFA performance is in good agreement with design parameters, with detector sensitivity of 2.2~mK$\sqrt{s}$ and diffraction limited beam sizes of 17.0''. On-sky measurements demonstrate a sensitivity of 70-90~mJy$\sqrt{s}$ per detector when operating under good atmospheric conditions (PWV below 1.0mm). With this performance the LFA regularly achieve a mapping sensitivity of 25~mJy when mapping a square degree in an hour. AMKID on APEX with its dual color observing capabilities, high sensitivity, large field-of-view and high angular resolution holds the promise to open a new range of science with the APEX telescope.
title AMKID -- a large KID-based camera at the APEX telescope
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2512.14905