Calibration Methods of Silicon Photomultiplier for JUNO-TAO Central Detector

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Xu, Jiayang, Li, Yichen, Liang, Zhan, Cao, Guofu, Chen, Zelin
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910199821893632
author Xu, Jiayang
Li, Yichen
Liang, Zhan
Cao, Guofu
Chen, Zelin
author_facet Xu, Jiayang
Li, Yichen
Liang, Zhan
Cao, Guofu
Chen, Zelin
contents The Taishan Antineutrino Observatory (TAO or JUNO-TAO) is a satellite observatory for the Jiangmen Underground Neutrino Observatory (JUNO), located 44 meters away from the No.1 reactor of the Taishan Nuclear Power Plant. TAO can measure the reactor antineutrino energy spectrum with excellent energy resolution (better than 2% at 1 MeV) using state-of-the-art Silicon Photomultipliers (SiPMs) operated at low temperature. To achieve this goal, the SiPMs (together with their readout electronics) must be well calibrated. This paper presents the channel-level calibration methods for the dark count rate (DCR), relative photon detection efficiency (PDE), time offset, gain, and internal optical crosstalk (IOCT) of the SiPMs based on charge and time information of the collected events. For the tile-level calibration of the external optical crosstalk (EOCT), in terms of its rate and emission angle distribution, a novel method is proposed by switching on and off different groups of SiPMs with an LED placed in the detector. Using one million simulated events, the expected calibration biases are evaluated for all the aforementioned parameters: relative PDE (~3%), IOCT (1.4%), DCR (0.4%), EOCT Rate (<0.1%), gain (<0.1%), time offset (<0.2 ns). The emission angle distribution of the EOCT photons could be measured with a bias of less than 4% in the main angular range. With the this calibration accuracy, the overall impacts of SiPM parameter uncertainties and calibration biases on vertex precision and energy resolution are limited, with relative degradation below 2% and 3%, respectively. It verifies the validity of the calibration method for the JUNO-TAO detector.
format Preprint
id arxiv_https___arxiv_org_abs_2512_15264
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Calibration Methods of Silicon Photomultiplier for JUNO-TAO Central Detector
Xu, Jiayang
Li, Yichen
Liang, Zhan
Cao, Guofu
Chen, Zelin
Instrumentation and Detectors
The Taishan Antineutrino Observatory (TAO or JUNO-TAO) is a satellite observatory for the Jiangmen Underground Neutrino Observatory (JUNO), located 44 meters away from the No.1 reactor of the Taishan Nuclear Power Plant. TAO can measure the reactor antineutrino energy spectrum with excellent energy resolution (better than 2% at 1 MeV) using state-of-the-art Silicon Photomultipliers (SiPMs) operated at low temperature. To achieve this goal, the SiPMs (together with their readout electronics) must be well calibrated. This paper presents the channel-level calibration methods for the dark count rate (DCR), relative photon detection efficiency (PDE), time offset, gain, and internal optical crosstalk (IOCT) of the SiPMs based on charge and time information of the collected events. For the tile-level calibration of the external optical crosstalk (EOCT), in terms of its rate and emission angle distribution, a novel method is proposed by switching on and off different groups of SiPMs with an LED placed in the detector. Using one million simulated events, the expected calibration biases are evaluated for all the aforementioned parameters: relative PDE (~3%), IOCT (1.4%), DCR (0.4%), EOCT Rate (<0.1%), gain (<0.1%), time offset (<0.2 ns). The emission angle distribution of the EOCT photons could be measured with a bias of less than 4% in the main angular range. With the this calibration accuracy, the overall impacts of SiPM parameter uncertainties and calibration biases on vertex precision and energy resolution are limited, with relative degradation below 2% and 3%, respectively. It verifies the validity of the calibration method for the JUNO-TAO detector.
title Calibration Methods of Silicon Photomultiplier for JUNO-TAO Central Detector
topic Instrumentation and Detectors
url https://arxiv.org/abs/2512.15264