Aerogel RICH Counter at the Belle II Detector
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2025
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866915692182241280 |
|---|---|
| author | Adachi, I. Akopov, N. Augueste, D. Bonis, J. Burmistrov, L. Dey, S. Dolenec, R. Ghevondyan, G. Giordano, R. Hvala, A. Iijima, T. Iwata, S. Kakuno, H. Karyan, G. Kawai, H. Kohriki, T. Konno, T. Korpar, S. Krizan, P. Kurokawa, S. Lai, Y. Lozar, A. Mrvar, M. Nazaryan, G. Nishida, S. Ogawa, S. Pestotnik, R. Prudiiev, I. Santelj, L. Seljak, A. Senekovic, L. Shoji, M. Spenko, K. Sumiyoshi, T. Tabata, M. Uno, K. Waheed, E. Yonenaga, M. Yusa, Y. |
| author_facet | Adachi, I. Akopov, N. Augueste, D. Bonis, J. Burmistrov, L. Dey, S. Dolenec, R. Ghevondyan, G. Giordano, R. Hvala, A. Iijima, T. Iwata, S. Kakuno, H. Karyan, G. Kawai, H. Kohriki, T. Konno, T. Korpar, S. Krizan, P. Kurokawa, S. Lai, Y. Lozar, A. Mrvar, M. Nazaryan, G. Nishida, S. Ogawa, S. Pestotnik, R. Prudiiev, I. Santelj, L. Seljak, A. Senekovic, L. Shoji, M. Spenko, K. Sumiyoshi, T. Tabata, M. Uno, K. Waheed, E. Yonenaga, M. Yusa, Y. |
| contents | We report on the design, operation, and performance of a novel proximity-focusing Ring Imaging Cherenkov (RICH) detector equipped with a multilayer focusing aerogel radiator, developed for the forward region of the Belle II spectrometer at the SuperKEKB $e^+e^-$ collider. The system achieves effective separation of charged pions, kaons, and protons across the full kinematic range of the experiment, from 0.5 GeV/c to 4 GeV/c. To date, the detector has successfully operated in data-taking, contributing to the collection and analysis of nearly 600/fb of Belle II $e^+e^-$ collision data. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2512_19146 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Aerogel RICH Counter at the Belle II Detector Adachi, I. Akopov, N. Augueste, D. Bonis, J. Burmistrov, L. Dey, S. Dolenec, R. Ghevondyan, G. Giordano, R. Hvala, A. Iijima, T. Iwata, S. Kakuno, H. Karyan, G. Kawai, H. Kohriki, T. Konno, T. Korpar, S. Krizan, P. Kurokawa, S. Lai, Y. Lozar, A. Mrvar, M. Nazaryan, G. Nishida, S. Ogawa, S. Pestotnik, R. Prudiiev, I. Santelj, L. Seljak, A. Senekovic, L. Shoji, M. Spenko, K. Sumiyoshi, T. Tabata, M. Uno, K. Waheed, E. Yonenaga, M. Yusa, Y. High Energy Physics - Experiment Instrumentation and Detectors We report on the design, operation, and performance of a novel proximity-focusing Ring Imaging Cherenkov (RICH) detector equipped with a multilayer focusing aerogel radiator, developed for the forward region of the Belle II spectrometer at the SuperKEKB $e^+e^-$ collider. The system achieves effective separation of charged pions, kaons, and protons across the full kinematic range of the experiment, from 0.5 GeV/c to 4 GeV/c. To date, the detector has successfully operated in data-taking, contributing to the collection and analysis of nearly 600/fb of Belle II $e^+e^-$ collision data. |
| title | Aerogel RICH Counter at the Belle II Detector |
| topic | High Energy Physics - Experiment Instrumentation and Detectors |
| url | https://arxiv.org/abs/2512.19146 |