Optical design and characterization of a multi-depth vision simulator

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Zolfaghari, Parviz, Varasteh, Ehsan, Kavakli, Koray, Gulersoy, Arda, Sahin, Afsun, Urey, Hakan
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917163173937152
author Zolfaghari, Parviz
Varasteh, Ehsan
Kavakli, Koray
Gulersoy, Arda
Sahin, Afsun
Urey, Hakan
author_facet Zolfaghari, Parviz
Varasteh, Ehsan
Kavakli, Koray
Gulersoy, Arda
Sahin, Afsun
Urey, Hakan
contents We present a vision simulator device (Katsim), a compact near-eye optical display designed for assessing postoperative corrected vision, preoperative intraocular lens (IOL) assessment, and objective IOL characterization. The system forms a virtual image using an amplitude-modulated LCoS spatial light modulator (AM-SLM), RGB LED illumination, and a high-speed varifocal lens. In the proposed architecture, the LED illumination and varifocal lens diopter changes are triggered in synchrony with the SLM RGB subframes, rendering three depth planes perceptually simultaneously via high-frequency time-multiplexing. Operating at 60 frames per second (fps), the system achieves an effective 180 Hz depth-coded cycle, enabling sharp, multi-depth rendering within a dynamically adjustable depth range from 0.2 m to optical infinity. The system's eyebox is configurable from 1 to 5 mm, while maintaining a fixed spatial location and preserving angular magnification regardless of changes in focus or eyebox size. The designed system features a 9.15-degree field of view. An integrated infrared pupil-tracking module detects non-cataractous regions of the cataractous crystalline lens, and the projected imagery is mechanically steered through those clear zones in real time. The proposed vision simulator supports both subjective simulation of post-surgical vision for patient-specific counseling and objective optical evaluation of IOLs, including resolution and contrast fidelity (e.g., modulation transfer function, contrast transfer function, and defocus curves). By decoupling depth modulation from eyebox position and size, the system offers a modular, portable platform that supports enhanced preoperative planning, personalized IOL selection, objective IOL characterization, and use as a novel research vision tool.
format Preprint
id arxiv_https___arxiv_org_abs_2512_19168
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Optical design and characterization of a multi-depth vision simulator
Zolfaghari, Parviz
Varasteh, Ehsan
Kavakli, Koray
Gulersoy, Arda
Sahin, Afsun
Urey, Hakan
Optics
Systems and Control
We present a vision simulator device (Katsim), a compact near-eye optical display designed for assessing postoperative corrected vision, preoperative intraocular lens (IOL) assessment, and objective IOL characterization. The system forms a virtual image using an amplitude-modulated LCoS spatial light modulator (AM-SLM), RGB LED illumination, and a high-speed varifocal lens. In the proposed architecture, the LED illumination and varifocal lens diopter changes are triggered in synchrony with the SLM RGB subframes, rendering three depth planes perceptually simultaneously via high-frequency time-multiplexing. Operating at 60 frames per second (fps), the system achieves an effective 180 Hz depth-coded cycle, enabling sharp, multi-depth rendering within a dynamically adjustable depth range from 0.2 m to optical infinity. The system's eyebox is configurable from 1 to 5 mm, while maintaining a fixed spatial location and preserving angular magnification regardless of changes in focus or eyebox size. The designed system features a 9.15-degree field of view. An integrated infrared pupil-tracking module detects non-cataractous regions of the cataractous crystalline lens, and the projected imagery is mechanically steered through those clear zones in real time. The proposed vision simulator supports both subjective simulation of post-surgical vision for patient-specific counseling and objective optical evaluation of IOLs, including resolution and contrast fidelity (e.g., modulation transfer function, contrast transfer function, and defocus curves). By decoupling depth modulation from eyebox position and size, the system offers a modular, portable platform that supports enhanced preoperative planning, personalized IOL selection, objective IOL characterization, and use as a novel research vision tool.
title Optical design and characterization of a multi-depth vision simulator
topic Optics
Systems and Control
url https://arxiv.org/abs/2512.19168