Patlak Parametric Image Estimation from Dynamic PET Using Diffusion Model Prior

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Huang, Ziqian, Yu, Boxiao, Li, Siqi, Ozdemir, Savas, Bae, Sangjin, Lee, Jae Sung, Wang, Guobao, Gong, Kuang
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866915691208114176
author Huang, Ziqian
Yu, Boxiao
Li, Siqi
Ozdemir, Savas
Bae, Sangjin
Lee, Jae Sung
Wang, Guobao
Gong, Kuang
author_facet Huang, Ziqian
Yu, Boxiao
Li, Siqi
Ozdemir, Savas
Bae, Sangjin
Lee, Jae Sung
Wang, Guobao
Gong, Kuang
contents Dynamic PET enables the quantitative estimation of physiology-related parameters and is widely utilized in research and increasingly adopted in clinical settings. Parametric imaging in dynamic PET requires kinetic modeling to estimate voxel-wise physiological parameters based on specific kinetic models. However, parametric images estimated through kinetic model fitting often suffer from low image quality due to the inherently ill-posed nature of the fitting process and the limited counts resulting from non-continuous data acquisition across multiple bed positions in whole-body PET. In this work, we proposed a diffusion model-based kinetic modeling framework for parametric image estimation, using the Patlak model as an example. The score function of the diffusion model was pre-trained on static total-body PET images and served as a prior for both Patlak slope and intercept images by leveraging their patch-wise similarity. During inference, the kinetic model was incorporated as a data-consistency constraint to guide the parametric image estimation. The proposed framework was evaluated on total-body dynamic PET datasets with different dose levels, demonstrating the feasibility and promising performance of the proposed framework in improving parametric image quality.
format Preprint
id arxiv_https___arxiv_org_abs_2512_19584
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Patlak Parametric Image Estimation from Dynamic PET Using Diffusion Model Prior
Huang, Ziqian
Yu, Boxiao
Li, Siqi
Ozdemir, Savas
Bae, Sangjin
Lee, Jae Sung
Wang, Guobao
Gong, Kuang
Image and Video Processing
Computer Vision and Pattern Recognition
Medical Physics
Dynamic PET enables the quantitative estimation of physiology-related parameters and is widely utilized in research and increasingly adopted in clinical settings. Parametric imaging in dynamic PET requires kinetic modeling to estimate voxel-wise physiological parameters based on specific kinetic models. However, parametric images estimated through kinetic model fitting often suffer from low image quality due to the inherently ill-posed nature of the fitting process and the limited counts resulting from non-continuous data acquisition across multiple bed positions in whole-body PET. In this work, we proposed a diffusion model-based kinetic modeling framework for parametric image estimation, using the Patlak model as an example. The score function of the diffusion model was pre-trained on static total-body PET images and served as a prior for both Patlak slope and intercept images by leveraging their patch-wise similarity. During inference, the kinetic model was incorporated as a data-consistency constraint to guide the parametric image estimation. The proposed framework was evaluated on total-body dynamic PET datasets with different dose levels, demonstrating the feasibility and promising performance of the proposed framework in improving parametric image quality.
title Patlak Parametric Image Estimation from Dynamic PET Using Diffusion Model Prior
topic Image and Video Processing
Computer Vision and Pattern Recognition
Medical Physics
url https://arxiv.org/abs/2512.19584