Design, construction, and testing of the PandaX-xT cryogenics system

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Wang, Xu, Zhao, Li, Xiao, Xiang, Cui, Xiangyi, Li, Shuaijie, Liu, Jianglai
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911737554403328
author Wang, Xu
Zhao, Li
Xiao, Xiang
Cui, Xiangyi
Li, Shuaijie
Liu, Jianglai
author_facet Wang, Xu
Zhao, Li
Xiao, Xiang
Cui, Xiangyi
Li, Shuaijie
Liu, Jianglai
contents The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifically designed to maintain the cold finger's temperature at the desired setpoint. The performance of the cooling tower and the coil has been tested. The cryogenics system with two cooling towers has achieved about 1900~W cooling power at 178~K. The liquid nitrogen coil provides emergency cooling power of more than 1500~W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210~kPa.
format Preprint
id arxiv_https___arxiv_org_abs_2512_23974
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Design, construction, and testing of the PandaX-xT cryogenics system
Wang, Xu
Zhao, Li
Xiao, Xiang
Cui, Xiangyi
Li, Shuaijie
Liu, Jianglai
Instrumentation and Detectors
The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifically designed to maintain the cold finger's temperature at the desired setpoint. The performance of the cooling tower and the coil has been tested. The cryogenics system with two cooling towers has achieved about 1900~W cooling power at 178~K. The liquid nitrogen coil provides emergency cooling power of more than 1500~W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210~kPa.
title Design, construction, and testing of the PandaX-xT cryogenics system
topic Instrumentation and Detectors
url https://arxiv.org/abs/2512.23974