Waste-to-Energy-Coupled AI Data Centers: Cooling Efficiency and Grid Resilience

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: He, Qi, Qu, Chunyu
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909978973962240
author He, Qi
Qu, Chunyu
author_facet He, Qi
Qu, Chunyu
contents AI data-center expansion is increasingly constrained by the coupled availability of deliverable electricity and heat-rejection (cooling) capacity. We propose and evaluate an integrated Waste-to-Energy-AI Data Center configuration that treats cooling as a first-class energy service rather than an unavoidable electricity burden. The coupled system is modeled as an input-output 'black box' with transparent boundaries and a standalone benchmark in which mechanical chilling is powered by grid electricity. The central mechanism is energy-grade matching: low-grade WtE thermal output drives absorption cooling to deliver chilled service, thereby displacing baseline cooling electricity. We show that thermoeconomic superiority is governed by three first-order determinants, (i) cooling coverage of IT heat load, (ii) parasitic electricity for transport and auxiliaries, and (iii) distance-driven delivery decay, yielding a break-even corridor beyond which net benefits vanish. Comparative statics characterize sensitivity to IT utilization, feedstock quality (waste LHV and throughput), climate parameterization, and corridor distance. We translate these accounting gains into decision language through a computable prototype for Levelized Cost of Computing (LCOC) and an ESG valuation channel grounded in measurable mechanisms, without re-deriving full lifecycle inventories. The framework provides siting-ready feasibility conditions for WtE-AIDC coupling in urban AI corridors under grid stress.
format Preprint
id arxiv_https___arxiv_org_abs_2512_24683
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Waste-to-Energy-Coupled AI Data Centers: Cooling Efficiency and Grid Resilience
He, Qi
Qu, Chunyu
Systems and Control
AI data-center expansion is increasingly constrained by the coupled availability of deliverable electricity and heat-rejection (cooling) capacity. We propose and evaluate an integrated Waste-to-Energy-AI Data Center configuration that treats cooling as a first-class energy service rather than an unavoidable electricity burden. The coupled system is modeled as an input-output 'black box' with transparent boundaries and a standalone benchmark in which mechanical chilling is powered by grid electricity. The central mechanism is energy-grade matching: low-grade WtE thermal output drives absorption cooling to deliver chilled service, thereby displacing baseline cooling electricity. We show that thermoeconomic superiority is governed by three first-order determinants, (i) cooling coverage of IT heat load, (ii) parasitic electricity for transport and auxiliaries, and (iii) distance-driven delivery decay, yielding a break-even corridor beyond which net benefits vanish. Comparative statics characterize sensitivity to IT utilization, feedstock quality (waste LHV and throughput), climate parameterization, and corridor distance. We translate these accounting gains into decision language through a computable prototype for Levelized Cost of Computing (LCOC) and an ESG valuation channel grounded in measurable mechanisms, without re-deriving full lifecycle inventories. The framework provides siting-ready feasibility conditions for WtE-AIDC coupling in urban AI corridors under grid stress.
title Waste-to-Energy-Coupled AI Data Centers: Cooling Efficiency and Grid Resilience
topic Systems and Control
url https://arxiv.org/abs/2512.24683