A Low Background Beta Detection System using a Time Projection Chamber

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Zhang, Ruiyang, Zhang, Zhiyong, Huang, Zengxuan, Zhou, Yong, Liu, Jianbei, Tang, Songsong, Cheng, Yuanfei, Feng, Changqing, Shao, Ming, Zhou, Yi
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917178229391360
author Zhang, Ruiyang
Zhang, Zhiyong
Huang, Zengxuan
Zhou, Yong
Liu, Jianbei
Tang, Songsong
Cheng, Yuanfei
Feng, Changqing
Shao, Ming
Zhou, Yi
author_facet Zhang, Ruiyang
Zhang, Zhiyong
Huang, Zengxuan
Zhou, Yong
Liu, Jianbei
Tang, Songsong
Cheng, Yuanfei
Feng, Changqing
Shao, Ming
Zhou, Yi
contents In this paper, we present a Time Projection Chamber (TPC) system for low-background beta radiation measurements. The system consists of a TPC with two-dimensional-strip readout Micromegas and an anti-coincidence detector with readout pads for cosmic ray veto. The detector system utilize an AGET-based waveform sampling system for data acquisition. The beta detection capability of the system was verified through experimental test using $^{90}$Sr beta source. Additionally, a dedicated simulation program based on Geant4 was developed to model the entire detection process, including responses to both the beta source and background radiation. Simulation results were compared with experimental data for both beta and background samples, showing good agreements. The simulation samples were utilized to optimize and train classification models for beta and background discrimination. By applying the selected model into test data, the system achieved a background rate of 0.49 $\rm cpm/cm^2$ while retaining more than 55% of $^{90}$Sr beta signals within a 7 cm diameter detection region. Further analysis revealed that approximately 70% of the background originates from environmental gamma radiation, while the remaining contribution mainly comes from intrinsic radioactivity of detector materials, particularly the FR-4 based field cage and readout plane. Based on the knowledge gained from the experiments and simulations, an optimization of the TPC system has been proposed, with simulation predicting a potential reduction of the background rate to 0.0012 $\rm cpm/cm^2$.
format Preprint
id arxiv_https___arxiv_org_abs_2512_24837
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A Low Background Beta Detection System using a Time Projection Chamber
Zhang, Ruiyang
Zhang, Zhiyong
Huang, Zengxuan
Zhou, Yong
Liu, Jianbei
Tang, Songsong
Cheng, Yuanfei
Feng, Changqing
Shao, Ming
Zhou, Yi
Instrumentation and Detectors
Nuclear Experiment
In this paper, we present a Time Projection Chamber (TPC) system for low-background beta radiation measurements. The system consists of a TPC with two-dimensional-strip readout Micromegas and an anti-coincidence detector with readout pads for cosmic ray veto. The detector system utilize an AGET-based waveform sampling system for data acquisition. The beta detection capability of the system was verified through experimental test using $^{90}$Sr beta source. Additionally, a dedicated simulation program based on Geant4 was developed to model the entire detection process, including responses to both the beta source and background radiation. Simulation results were compared with experimental data for both beta and background samples, showing good agreements. The simulation samples were utilized to optimize and train classification models for beta and background discrimination. By applying the selected model into test data, the system achieved a background rate of 0.49 $\rm cpm/cm^2$ while retaining more than 55% of $^{90}$Sr beta signals within a 7 cm diameter detection region. Further analysis revealed that approximately 70% of the background originates from environmental gamma radiation, while the remaining contribution mainly comes from intrinsic radioactivity of detector materials, particularly the FR-4 based field cage and readout plane. Based on the knowledge gained from the experiments and simulations, an optimization of the TPC system has been proposed, with simulation predicting a potential reduction of the background rate to 0.0012 $\rm cpm/cm^2$.
title A Low Background Beta Detection System using a Time Projection Chamber
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2512.24837