Towards a temperature-insensitive composite diamond clock

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Lourette, Sean, Jarmola, Andrey, Chathanathil, Jabir, Acosta, Victor M., Birdwell, A. Glen, Blümler, Peter, Budker, Dmitry, Carrasco, Sebastián C., Ivanov, Tony G., Kolkowitz, Shimon, Malinovsky, Vladimir S.
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866918268610019328
author Lourette, Sean
Jarmola, Andrey
Chathanathil, Jabir
Acosta, Victor M.
Birdwell, A. Glen
Blümler, Peter
Budker, Dmitry
Carrasco, Sebastián C.
Ivanov, Tony G.
Kolkowitz, Shimon
Malinovsky, Vladimir S.
author_facet Lourette, Sean
Jarmola, Andrey
Chathanathil, Jabir
Acosta, Victor M.
Birdwell, A. Glen
Blümler, Peter
Budker, Dmitry
Carrasco, Sebastián C.
Ivanov, Tony G.
Kolkowitz, Shimon
Malinovsky, Vladimir S.
contents Frequency references based on solid state spins promise simplicity, compactness, robustness, multifunctionality, ease of integration, and high densities of emitters. Nitrogen-vacancy (NV) centers in diamond are a natural candidate, but the electronic zero-field splitting exhibits a large fractional temperature dependence, which has precluded its use as a stable clock transition. Here we show that this limitation can be overcome by forming a composite frequency reference that combines measurements of the electronic splitting D with the nuclear quadrupole splitting of the $^{14}$N nuclear spin intrinsic to the NV center. We further benchmark this composite approach against alternative strategies for mitigating temperature sensitivity. By implementing a specially designed pulse sequence with an eight-phase control scheme that suppresses pulse imperfections, we interleave measurements of D and Q in a high-density NV ensemble and demonstrate a temperature-compensated composite frequency reference. The stability of this composite diamond clock is characterized over a 10-day period at room temperature through a comparison to a Rb vapor-cell clock, yielding a fractional instability below $5 \times 10^{-9}$ for an averaging time of $τ= 200$ s and below $1 \times 10^{-8}$ at $τ= 2 \times 10^5$ s, corresponding to measured improvements by a factor of 4 and 200, respectively, over a clock based purely on the single frequency D for the same periods. By characterizing the residual sensitivity to magnetic fields, optical power, and radio-frequency drive amplitudes, we find that temperature is no longer the dominant source of instability. These results establish complementary electron- and nuclear-spin transitions in diamond as a viable route to thermally robust frequency metrology, providing a pathway toward compact, multifunctional solid-state clocks and quantum sensors.
format Preprint
id arxiv_https___arxiv_org_abs_2601_00157
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Towards a temperature-insensitive composite diamond clock
Lourette, Sean
Jarmola, Andrey
Chathanathil, Jabir
Acosta, Victor M.
Birdwell, A. Glen
Blümler, Peter
Budker, Dmitry
Carrasco, Sebastián C.
Ivanov, Tony G.
Kolkowitz, Shimon
Malinovsky, Vladimir S.
Quantum Physics
Applied Physics
Atomic Physics
Instrumentation and Detectors
Frequency references based on solid state spins promise simplicity, compactness, robustness, multifunctionality, ease of integration, and high densities of emitters. Nitrogen-vacancy (NV) centers in diamond are a natural candidate, but the electronic zero-field splitting exhibits a large fractional temperature dependence, which has precluded its use as a stable clock transition. Here we show that this limitation can be overcome by forming a composite frequency reference that combines measurements of the electronic splitting D with the nuclear quadrupole splitting of the $^{14}$N nuclear spin intrinsic to the NV center. We further benchmark this composite approach against alternative strategies for mitigating temperature sensitivity. By implementing a specially designed pulse sequence with an eight-phase control scheme that suppresses pulse imperfections, we interleave measurements of D and Q in a high-density NV ensemble and demonstrate a temperature-compensated composite frequency reference. The stability of this composite diamond clock is characterized over a 10-day period at room temperature through a comparison to a Rb vapor-cell clock, yielding a fractional instability below $5 \times 10^{-9}$ for an averaging time of $τ= 200$ s and below $1 \times 10^{-8}$ at $τ= 2 \times 10^5$ s, corresponding to measured improvements by a factor of 4 and 200, respectively, over a clock based purely on the single frequency D for the same periods. By characterizing the residual sensitivity to magnetic fields, optical power, and radio-frequency drive amplitudes, we find that temperature is no longer the dominant source of instability. These results establish complementary electron- and nuclear-spin transitions in diamond as a viable route to thermally robust frequency metrology, providing a pathway toward compact, multifunctional solid-state clocks and quantum sensors.
title Towards a temperature-insensitive composite diamond clock
topic Quantum Physics
Applied Physics
Atomic Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2601.00157