A 2.5 $μ$W 30 nV/$\surd$Hz Instrumentation Amplifier for Bioimpedance Sensors with Source Degenerated Current Mirror and DTMOS Transistor
Fuente:
arXiv
Guardado en:
| Autores principales: | , |
|---|---|
| Formato: | Preprint |
| Publicado: |
2026
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1866911352840257536 |
|---|---|
| author | Xue, Yu Kim, Kwantae |
| author_facet | Xue, Yu Kim, Kwantae |
| contents | This paper proposes a low-power and low-noise instrumentation amplifier (IA) tailored for bioimpedance sensing applications. The design originates from a gain-boosted flipped voltage follower (FVF) transconductance (TC) stage and integrates two complementary circuit techniques to improve the noise performance. To achieve an optimal balance between input-referred noise and available voltage headroom, a source-degenerated current mirror (SDCM) is adopted, resulting in reducing the input-referred noise by 7.95% compared with a conventional current mirror structure. In addition, a dynamic threshold MOSFET (DTMOS) scheme is employed to enhance the effective transconductance, leading to a further 11.66% reduction in input-referred noise. Simulated in a 28 nm CMOS process demonstrate that the proposed IA achieves an input-referred noise floor of 30 nV/$\surd$Hz and a bandwidth of 1.44 MHz, while consuming only 2.5 $μ$W from a 0.8 V supply. Compared to the baseline design, the proposed approach achieves a 32.4% reduction in power consumption without degrading noise performance. The complete design parameters are open-sourced in this paper, to ensure reproducibility and facilitate future developments. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2601_01232 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | A 2.5 $μ$W 30 nV/$\surd$Hz Instrumentation Amplifier for Bioimpedance Sensors with Source Degenerated Current Mirror and DTMOS Transistor Xue, Yu Kim, Kwantae Signal Processing This paper proposes a low-power and low-noise instrumentation amplifier (IA) tailored for bioimpedance sensing applications. The design originates from a gain-boosted flipped voltage follower (FVF) transconductance (TC) stage and integrates two complementary circuit techniques to improve the noise performance. To achieve an optimal balance between input-referred noise and available voltage headroom, a source-degenerated current mirror (SDCM) is adopted, resulting in reducing the input-referred noise by 7.95% compared with a conventional current mirror structure. In addition, a dynamic threshold MOSFET (DTMOS) scheme is employed to enhance the effective transconductance, leading to a further 11.66% reduction in input-referred noise. Simulated in a 28 nm CMOS process demonstrate that the proposed IA achieves an input-referred noise floor of 30 nV/$\surd$Hz and a bandwidth of 1.44 MHz, while consuming only 2.5 $μ$W from a 0.8 V supply. Compared to the baseline design, the proposed approach achieves a 32.4% reduction in power consumption without degrading noise performance. The complete design parameters are open-sourced in this paper, to ensure reproducibility and facilitate future developments. |
| title | A 2.5 $μ$W 30 nV/$\surd$Hz Instrumentation Amplifier for Bioimpedance Sensors with Source Degenerated Current Mirror and DTMOS Transistor |
| topic | Signal Processing |
| url | https://arxiv.org/abs/2601.01232 |