Common Iron Passive Magnetic Shielding for Scintillator Array Photomultiplier Tubes

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Atovullaev, T., Cherepanov, S., Atovullaeva, A., Kahlbow, J., Patsyuk, M., Hen, O., Johansson, G., Kruglova, I., Meirovich, B., Nepochatykh, S., Piasetzky, E., Piyadin, S., Salamatin, A., Sedykh, S., Segev, S., Zhang, Y.
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917183439765504
author Atovullaev, T.
Cherepanov, S.
Atovullaeva, A.
Kahlbow, J.
Patsyuk, M.
Hen, O.
Johansson, G.
Kruglova, I.
Meirovich, B.
Nepochatykh, S.
Piasetzky, E.
Piyadin, S.
Salamatin, A.
Sedykh, S.
Segev, S.
Zhang, Y.
author_facet Atovullaev, T.
Cherepanov, S.
Atovullaeva, A.
Kahlbow, J.
Patsyuk, M.
Hen, O.
Johansson, G.
Kruglova, I.
Meirovich, B.
Nepochatykh, S.
Piasetzky, E.
Piyadin, S.
Salamatin, A.
Sedykh, S.
Segev, S.
Zhang, Y.
contents In accelerator-based experiments, detector arrays constructed from organic plastic scintillators are widely used for measurements of particle timing, hit position, and energy loss. These detectors are often operated in proximity to magnetic spectrometers, where the associated photomultiplier tubes (PMTs) are exposed to fringe magnetic fields. The standard approach to mitigate magnetic interference involves individually shielding each PMT. In this work, we present a combined passive shielding solution consisting of a common iron enclosure for a row of PMTs, supplemented with individual mu-metal cylinders. This configuration was deployed during a 2022 experiment at JINR. Performance evaluations show that the proposed shielding effectively preserves PMT gain and timing resolution, demonstrating its viability for future applications in similar experimental environments.
format Preprint
id arxiv_https___arxiv_org_abs_2601_01636
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Common Iron Passive Magnetic Shielding for Scintillator Array Photomultiplier Tubes
Atovullaev, T.
Cherepanov, S.
Atovullaeva, A.
Kahlbow, J.
Patsyuk, M.
Hen, O.
Johansson, G.
Kruglova, I.
Meirovich, B.
Nepochatykh, S.
Piasetzky, E.
Piyadin, S.
Salamatin, A.
Sedykh, S.
Segev, S.
Zhang, Y.
Instrumentation and Detectors
Nuclear Experiment
In accelerator-based experiments, detector arrays constructed from organic plastic scintillators are widely used for measurements of particle timing, hit position, and energy loss. These detectors are often operated in proximity to magnetic spectrometers, where the associated photomultiplier tubes (PMTs) are exposed to fringe magnetic fields. The standard approach to mitigate magnetic interference involves individually shielding each PMT. In this work, we present a combined passive shielding solution consisting of a common iron enclosure for a row of PMTs, supplemented with individual mu-metal cylinders. This configuration was deployed during a 2022 experiment at JINR. Performance evaluations show that the proposed shielding effectively preserves PMT gain and timing resolution, demonstrating its viability for future applications in similar experimental environments.
title Common Iron Passive Magnetic Shielding for Scintillator Array Photomultiplier Tubes
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2601.01636