Machine Learning Guided Cooling System Optimization for Data Center

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Jadhav, Shrenik, Liu, Zheng
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911494862536704
author Jadhav, Shrenik
Liu, Zheng
author_facet Jadhav, Shrenik
Liu, Zheng
contents Effective data center cooling is crucial for reliable operation; however, cooling systems often exhibit inefficiencies that result in excessive energy consumption. This paper presents a three-stage, physics-guided machine learning framework for identifying and reducing cooling energy waste in high-performance computing facilities. Using one year of 10-minute resolution operational data from the Frontier exascale supercomputer, we first train a monotonicity-constrained gradient boosting surrogate that predicts facility accessory power from coolant flow rates, temperatures, and server power. The surrogate achieves a mean absolute error of 0.026 MW and predicts power usage effectiveness within 0.01 of measured values for 98.7% of test samples. In the second stage, the surrogate serves as a physics-consistent baseline to quantify excess cooling energy, revealing approximately 85 MWh of annual inefficiency concentrated in specific months, hours, and operating regimes. The third stage evaluates guardrail-constrained counterfactual adjustments to supply temperature and subloop flows, demonstrating that up to 96% of identified excess can be recovered through small, safe setpoint changes while respecting thermal limits and operational constraints. The framework yields interpretable recommendations, supports counterfactual analyses such as flow reduction during low-load periods and redistribution of thermal duty across cooling loops, and provides a practical pathway toward quantifiable reductions in accessory power. The developed framework is readily compatible with model predictive control and provides a template that, with site-specific recalibration, could be adapted to other liquid-cooled data centers with different configurations and cooling requirements.
format Preprint
id arxiv_https___arxiv_org_abs_2601_02275
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Machine Learning Guided Cooling System Optimization for Data Center
Jadhav, Shrenik
Liu, Zheng
Systems and Control
Applications
Effective data center cooling is crucial for reliable operation; however, cooling systems often exhibit inefficiencies that result in excessive energy consumption. This paper presents a three-stage, physics-guided machine learning framework for identifying and reducing cooling energy waste in high-performance computing facilities. Using one year of 10-minute resolution operational data from the Frontier exascale supercomputer, we first train a monotonicity-constrained gradient boosting surrogate that predicts facility accessory power from coolant flow rates, temperatures, and server power. The surrogate achieves a mean absolute error of 0.026 MW and predicts power usage effectiveness within 0.01 of measured values for 98.7% of test samples. In the second stage, the surrogate serves as a physics-consistent baseline to quantify excess cooling energy, revealing approximately 85 MWh of annual inefficiency concentrated in specific months, hours, and operating regimes. The third stage evaluates guardrail-constrained counterfactual adjustments to supply temperature and subloop flows, demonstrating that up to 96% of identified excess can be recovered through small, safe setpoint changes while respecting thermal limits and operational constraints. The framework yields interpretable recommendations, supports counterfactual analyses such as flow reduction during low-load periods and redistribution of thermal duty across cooling loops, and provides a practical pathway toward quantifiable reductions in accessory power. The developed framework is readily compatible with model predictive control and provides a template that, with site-specific recalibration, could be adapted to other liquid-cooled data centers with different configurations and cooling requirements.
title Machine Learning Guided Cooling System Optimization for Data Center
topic Systems and Control
Applications
url https://arxiv.org/abs/2601.02275