Optimization of Cryogenic Detector Test Station by Rejecting Electromagnetic Interference

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Lee, Sangbaek, Armstrong, Whitney, DiPreta, Maximo, Dulya, Jacob, Novosad, Valentine, Polakovic, Tomas
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914236602515456
author Lee, Sangbaek
Armstrong, Whitney
DiPreta, Maximo
Dulya, Jacob
Novosad, Valentine
Polakovic, Tomas
author_facet Lee, Sangbaek
Armstrong, Whitney
DiPreta, Maximo
Dulya, Jacob
Novosad, Valentine
Polakovic, Tomas
contents We report on the solution optimized for characterizing SNSPDs by rejecting electromagnetic interference from various sources. The proposed readout method enhances measurement stability and enables reliable device characterization at low bias currents, where the signal-to-noise ratio is typically limited. By effectively suppressing EMI-induced noise, the method improves the ability to distinguish genuine detection events from spurious signals and reduces the effort required for data analysis. The approach has been applied to preliminary measurements of SNSPDs exposed to $α$ particles emitted from a $^{241}$Am source, demonstrating stable operation and clean signal acquisition. While a detailed study of $α$ detection is underway, the method establishes a foundation for further characterization of SNSPDs with various incident particles. The demonstrated EMI rejection technique is expected to facilitate future research in particle detection and support ongoing SNSPD development for applications in nuclear and accelerator-based experiments.
format Preprint
id arxiv_https___arxiv_org_abs_2601_03158
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Optimization of Cryogenic Detector Test Station by Rejecting Electromagnetic Interference
Lee, Sangbaek
Armstrong, Whitney
DiPreta, Maximo
Dulya, Jacob
Novosad, Valentine
Polakovic, Tomas
Instrumentation and Detectors
We report on the solution optimized for characterizing SNSPDs by rejecting electromagnetic interference from various sources. The proposed readout method enhances measurement stability and enables reliable device characterization at low bias currents, where the signal-to-noise ratio is typically limited. By effectively suppressing EMI-induced noise, the method improves the ability to distinguish genuine detection events from spurious signals and reduces the effort required for data analysis. The approach has been applied to preliminary measurements of SNSPDs exposed to $α$ particles emitted from a $^{241}$Am source, demonstrating stable operation and clean signal acquisition. While a detailed study of $α$ detection is underway, the method establishes a foundation for further characterization of SNSPDs with various incident particles. The demonstrated EMI rejection technique is expected to facilitate future research in particle detection and support ongoing SNSPD development for applications in nuclear and accelerator-based experiments.
title Optimization of Cryogenic Detector Test Station by Rejecting Electromagnetic Interference
topic Instrumentation and Detectors
url https://arxiv.org/abs/2601.03158