_version_ 1866914236646555648
author Parzych, Szymon
Niedźwiecki, Szymon
Beyene, Ermias Yitayew
Chug, Neha
Conti, Maurizio
Curceanu, Catalina
Czerwiński, Eryk
Das, Manish
Eliyan, Kavya Valsan
Hajduga, Jakub
Jalali, Sharareh
Kacprzak, Krzysztof
Kaplanoglu, Tevfik
Kapłon, Łukasz
Kasperska, Kamila
Khreptak, Aleksander
Korcyl, Grzegorz
Kozik, Tomasz
Kumar, Deepak
Venadan, Anoop Kunimmal
Kubat, Karol
Lisowski, Edward
Lisowski, Filip
Mędrala-Sowa, Justyna
Mryka, Wiktor
Moyo, Simbarashe
Pandey, Piyush
del Rio, Elena Perez
Porcelli, Alessio
Rachwał, Bartłomiej
Rädler, Martin
Rominger, Axel
Sharma, Sushil
Shi, Kuangyu
Skurzok, Magdalena
Steinberger, William M.
Szumlak, Tomasz
Tanty, Pooja
Ardebili, Keyvan Tayefi
Tiwari, Satyam
Stępień, Ewa Łucja
Moskal, Paweł
author_facet Parzych, Szymon
Niedźwiecki, Szymon
Beyene, Ermias Yitayew
Chug, Neha
Conti, Maurizio
Curceanu, Catalina
Czerwiński, Eryk
Das, Manish
Eliyan, Kavya Valsan
Hajduga, Jakub
Jalali, Sharareh
Kacprzak, Krzysztof
Kaplanoglu, Tevfik
Kapłon, Łukasz
Kasperska, Kamila
Khreptak, Aleksander
Korcyl, Grzegorz
Kozik, Tomasz
Kumar, Deepak
Venadan, Anoop Kunimmal
Kubat, Karol
Lisowski, Edward
Lisowski, Filip
Mędrala-Sowa, Justyna
Mryka, Wiktor
Moyo, Simbarashe
Pandey, Piyush
del Rio, Elena Perez
Porcelli, Alessio
Rachwał, Bartłomiej
Rädler, Martin
Rominger, Axel
Sharma, Sushil
Shi, Kuangyu
Skurzok, Magdalena
Steinberger, William M.
Szumlak, Tomasz
Tanty, Pooja
Ardebili, Keyvan Tayefi
Tiwari, Satyam
Stępień, Ewa Łucja
Moskal, Paweł
contents Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI.
format Preprint
id arxiv_https___arxiv_org_abs_2601_03172
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs
Parzych, Szymon
Niedźwiecki, Szymon
Beyene, Ermias Yitayew
Chug, Neha
Conti, Maurizio
Curceanu, Catalina
Czerwiński, Eryk
Das, Manish
Eliyan, Kavya Valsan
Hajduga, Jakub
Jalali, Sharareh
Kacprzak, Krzysztof
Kaplanoglu, Tevfik
Kapłon, Łukasz
Kasperska, Kamila
Khreptak, Aleksander
Korcyl, Grzegorz
Kozik, Tomasz
Kumar, Deepak
Venadan, Anoop Kunimmal
Kubat, Karol
Lisowski, Edward
Lisowski, Filip
Mędrala-Sowa, Justyna
Mryka, Wiktor
Moyo, Simbarashe
Pandey, Piyush
del Rio, Elena Perez
Porcelli, Alessio
Rachwał, Bartłomiej
Rädler, Martin
Rominger, Axel
Sharma, Sushil
Shi, Kuangyu
Skurzok, Magdalena
Steinberger, William M.
Szumlak, Tomasz
Tanty, Pooja
Ardebili, Keyvan Tayefi
Tiwari, Satyam
Stępień, Ewa Łucja
Moskal, Paweł
Medical Physics
Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI.
title Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs
topic Medical Physics
url https://arxiv.org/abs/2601.03172