Biomechanically Informed Image Registration for Patient-Specific Aortic Valve Strain Analysis

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Nakhaei, Mohsen, Pouch, Alison, Amin, Silvani, Daemer, Matthew, Herz, Christian, Yushkevich, Natalie, Ghofaily, Lourdes Al, Desai, Nimesh, Bavaria, Joseph, Jolley, Matthew, Wu, Wensi
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866912901612175360
author Nakhaei, Mohsen
Pouch, Alison
Amin, Silvani
Daemer, Matthew
Herz, Christian
Yushkevich, Natalie
Ghofaily, Lourdes Al
Desai, Nimesh
Bavaria, Joseph
Jolley, Matthew
Wu, Wensi
author_facet Nakhaei, Mohsen
Pouch, Alison
Amin, Silvani
Daemer, Matthew
Herz, Christian
Yushkevich, Natalie
Ghofaily, Lourdes Al
Desai, Nimesh
Bavaria, Joseph
Jolley, Matthew
Wu, Wensi
contents Aortic valve (AV) biomechanics play a critical role in maintaining normal cardiac function. Pathological variations, particularly in bicuspid aortic valves, alter leaflet loading, increase strain, and accelerate disease progression. Accurate patient-specific characterization of valve geometry and deformation is therefore essential for predicting disease progression and guiding durable repair. Current imaging and computational methods often fail to capture rapid valve motion and complex patient-specific features, limiting precise biomechanical assessment. To address these limitations, we developed an image registration framework coupled with the finite element method (FEM) to improve AV tracking and biomechanical evaluation. The valve geometries derived from 4D echocardiography and CT were used to simulate AV closure and generate intermediate deformation states. These FEM-generated states facilitated leaflet tracking, while image registration corrected misalignment between simulations and imaging data. In 20 patients, FEM-augmented registration improved accuracy by 40% compared with direct registration. This improvement enabled more reliable strain estimation by measuring leaflet deformation directly from imaging and reducing uncertainties associated with boundary conditions and material assumptions. Areal, Green-Lagrange, and deviatoric strains were quantified in adult trileaflet/bicuspid valves, as well as pediatric patients, revealing distinct deformation patterns across valve groups. Convergence in mean deviatoric strain between adult trileaflet and pediatric valves suggests volumetric deformation underlies age- and size-related differences in AV mechanics. The FEM-augmented registration enhances tracking and biomechanical evaluation accuracy, providing clinically relevant insights into patient-specific AV deformation to support individualized medical and intervention planning.
format Preprint
id arxiv_https___arxiv_org_abs_2601_04375
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Biomechanically Informed Image Registration for Patient-Specific Aortic Valve Strain Analysis
Nakhaei, Mohsen
Pouch, Alison
Amin, Silvani
Daemer, Matthew
Herz, Christian
Yushkevich, Natalie
Ghofaily, Lourdes Al
Desai, Nimesh
Bavaria, Joseph
Jolley, Matthew
Wu, Wensi
Quantitative Methods
Applied Physics
Aortic valve (AV) biomechanics play a critical role in maintaining normal cardiac function. Pathological variations, particularly in bicuspid aortic valves, alter leaflet loading, increase strain, and accelerate disease progression. Accurate patient-specific characterization of valve geometry and deformation is therefore essential for predicting disease progression and guiding durable repair. Current imaging and computational methods often fail to capture rapid valve motion and complex patient-specific features, limiting precise biomechanical assessment. To address these limitations, we developed an image registration framework coupled with the finite element method (FEM) to improve AV tracking and biomechanical evaluation. The valve geometries derived from 4D echocardiography and CT were used to simulate AV closure and generate intermediate deformation states. These FEM-generated states facilitated leaflet tracking, while image registration corrected misalignment between simulations and imaging data. In 20 patients, FEM-augmented registration improved accuracy by 40% compared with direct registration. This improvement enabled more reliable strain estimation by measuring leaflet deformation directly from imaging and reducing uncertainties associated with boundary conditions and material assumptions. Areal, Green-Lagrange, and deviatoric strains were quantified in adult trileaflet/bicuspid valves, as well as pediatric patients, revealing distinct deformation patterns across valve groups. Convergence in mean deviatoric strain between adult trileaflet and pediatric valves suggests volumetric deformation underlies age- and size-related differences in AV mechanics. The FEM-augmented registration enhances tracking and biomechanical evaluation accuracy, providing clinically relevant insights into patient-specific AV deformation to support individualized medical and intervention planning.
title Biomechanically Informed Image Registration for Patient-Specific Aortic Valve Strain Analysis
topic Quantitative Methods
Applied Physics
url https://arxiv.org/abs/2601.04375