Dosimetric Impact of Hidden Input Parameters in Inverse Optimization Algorithms for GYN HDR Brachytherapy

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Park, YeongHyeon, Su, Shiqin, Vijayan, Sarath, Yu, Zhiqian Henry, Cunningham, Mandy, Kim, Yusung
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917190747291648
author Park, YeongHyeon
Su, Shiqin
Vijayan, Sarath
Yu, Zhiqian Henry
Cunningham, Mandy
Kim, Yusung
author_facet Park, YeongHyeon
Su, Shiqin
Vijayan, Sarath
Yu, Zhiqian Henry
Cunningham, Mandy
Kim, Yusung
contents Inverse optimization (IO) algorithms are used in GYN HDR brachytherapy planning, with user parameter settings embedded in commercial TPS. To examine the dosimetric influence of hidden input parameters in three IO algorithms-IPSA, HIPO, and MCO-for GYN HDR brachytherapy across two applicator types. In-house implementations of IPSA, HIPO, and MCO were implemented and evaluated against retrospectively generated commercial TPS plans (Oncentra Brachy) using identical clinical input parameters across 24 cervical cancer cases (18 T&O; 6 T&O+Needles (T&O+N)). Each IO algorithm was assessed using 1k combinations of hidden parameters (e.g., dwell-time modulation constraints, convergence thresholds). Cumulative DVH curves and dosimetric indices (HR-CTV D98/D90, OAR D2cc) were compared with commercial plans. Standard deviations (SD) of DVH differences were used to characterize sensitivity to hidden parameters. For HR-CTV, SD values in T&O+N cases reached 23.0 Gy and 7.1 Gy for MCO and HIPO, respectively, with corresponding average values of 55.8 Gy and 19.7 Gy. In T&O cases, HR-CTV SD values reached 4.9 Gy and 3.3 Gy for HIPO and IPSA, respectively, with average values of 20.1 Gy and 8.6 Gy. MCO exhibited the highest sensitivity, followed by HIPO and IPSA. T&O+N cases showed greater sensitivity than T&O cases. Absolute differences in HR-CTV D90 (D98) relative to commercial algorithms reached up to 33.3 Gy (28.4) for T&O+N cases and 10.8 Gy (8.5) for T&O cases. For OARs, absolute D2cc differences in T&O+N (T&O) cases reached up to 8.6 Gy (2.3) for rectum, 17 Gy (10.2) for bladder, 14.8 Gy (3.9) for sigmoid, and 7.0 Gy (8.1) for bowel. Hidden input parameter settings significantly impact on GYN HDR plans, with target coverage up to 28.4 Gy across IO algorithms for both T&O and T&O+N cases. The findings in this study shown the potential to improve plans through hidden input parameter optimization.
format Preprint
id arxiv_https___arxiv_org_abs_2601_05045
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Dosimetric Impact of Hidden Input Parameters in Inverse Optimization Algorithms for GYN HDR Brachytherapy
Park, YeongHyeon
Su, Shiqin
Vijayan, Sarath
Yu, Zhiqian Henry
Cunningham, Mandy
Kim, Yusung
Medical Physics
Inverse optimization (IO) algorithms are used in GYN HDR brachytherapy planning, with user parameter settings embedded in commercial TPS. To examine the dosimetric influence of hidden input parameters in three IO algorithms-IPSA, HIPO, and MCO-for GYN HDR brachytherapy across two applicator types. In-house implementations of IPSA, HIPO, and MCO were implemented and evaluated against retrospectively generated commercial TPS plans (Oncentra Brachy) using identical clinical input parameters across 24 cervical cancer cases (18 T&O; 6 T&O+Needles (T&O+N)). Each IO algorithm was assessed using 1k combinations of hidden parameters (e.g., dwell-time modulation constraints, convergence thresholds). Cumulative DVH curves and dosimetric indices (HR-CTV D98/D90, OAR D2cc) were compared with commercial plans. Standard deviations (SD) of DVH differences were used to characterize sensitivity to hidden parameters. For HR-CTV, SD values in T&O+N cases reached 23.0 Gy and 7.1 Gy for MCO and HIPO, respectively, with corresponding average values of 55.8 Gy and 19.7 Gy. In T&O cases, HR-CTV SD values reached 4.9 Gy and 3.3 Gy for HIPO and IPSA, respectively, with average values of 20.1 Gy and 8.6 Gy. MCO exhibited the highest sensitivity, followed by HIPO and IPSA. T&O+N cases showed greater sensitivity than T&O cases. Absolute differences in HR-CTV D90 (D98) relative to commercial algorithms reached up to 33.3 Gy (28.4) for T&O+N cases and 10.8 Gy (8.5) for T&O cases. For OARs, absolute D2cc differences in T&O+N (T&O) cases reached up to 8.6 Gy (2.3) for rectum, 17 Gy (10.2) for bladder, 14.8 Gy (3.9) for sigmoid, and 7.0 Gy (8.1) for bowel. Hidden input parameter settings significantly impact on GYN HDR plans, with target coverage up to 28.4 Gy across IO algorithms for both T&O and T&O+N cases. The findings in this study shown the potential to improve plans through hidden input parameter optimization.
title Dosimetric Impact of Hidden Input Parameters in Inverse Optimization Algorithms for GYN HDR Brachytherapy
topic Medical Physics
url https://arxiv.org/abs/2601.05045