Motion Compensation for Real Time Ultrasound Scanning in Robotically Assisted Prostate Biopsy Procedures

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Markulin, Matija, Matijević, Luka, Siktar, Luka, Jurdana, Janko, Caran, Branimir, Švaco, Marko, Šuligoj, Filip, Šekoranja, Bojan
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915718662979584
author Markulin, Matija
Matijević, Luka
Siktar, Luka
Jurdana, Janko
Caran, Branimir
Švaco, Marko
Šuligoj, Filip
Šekoranja, Bojan
author_facet Markulin, Matija
Matijević, Luka
Siktar, Luka
Jurdana, Janko
Caran, Branimir
Švaco, Marko
Šuligoj, Filip
Šekoranja, Bojan
contents Prostate cancer is one of the most common types of cancer in men. Its diagnosis by biopsy requires a high level of expertise and precision from the surgeon, so the results are highly operator-dependent. The aim of this work is to develop a robotic system for assisted ultrasound (US) examination of the prostate, a prebiopsy step that could reduce the dexterity requirements and enable faster, more accurate and more available prostate biopsy. We developed and validated a laboratory setup with a collaborative robotic arm that can autonomously scan a prostate phantom and attached the phantom to a medical robotic arm that mimics the patient's movements. The scanning robot keeps the relative position of the US probe and the prostate constant, ensuring a consistent and robust approach to reconstructing the prostate. To reconstruct the prostate, each slice is segmented to generate a series of prostate contours converted into a 3D point cloud used for biopsy planning. The average scan time of the prostate was 30 s, and the average 3D reconstruction of the prostate took 3 s. We performed four motion scenarios: the phantom was scanned in a stationary state (S), with horizontal motion (H), with vertical motion (V), and with a combination of the two (C). System validation is performed by registering the prostate point cloud reconstructions acquired during different motions (H, V, C) with those obtained in the stationary state. ICP registration with a threshold of 0.8 mm yields mean 83.2\% fitness and 0.35 mm RMSE for S-H registration, 84.1\% fitness and 0.37 mm RMSE for S-V registration and 79.4\% fitness and 0.37 mm RMSE for S-C registration. Due to the elastic and soft material properties of the prostate phantom, the maximum robot tracking error was 3 mm, which can be sufficient for prostate biopsy according to medical literature. The maximum delay in motion compensation was 0.5 s.
format Preprint
id arxiv_https___arxiv_org_abs_2601_05661
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Motion Compensation for Real Time Ultrasound Scanning in Robotically Assisted Prostate Biopsy Procedures
Markulin, Matija
Matijević, Luka
Siktar, Luka
Jurdana, Janko
Caran, Branimir
Švaco, Marko
Šuligoj, Filip
Šekoranja, Bojan
Robotics
J.2.7; J.3.3
Prostate cancer is one of the most common types of cancer in men. Its diagnosis by biopsy requires a high level of expertise and precision from the surgeon, so the results are highly operator-dependent. The aim of this work is to develop a robotic system for assisted ultrasound (US) examination of the prostate, a prebiopsy step that could reduce the dexterity requirements and enable faster, more accurate and more available prostate biopsy. We developed and validated a laboratory setup with a collaborative robotic arm that can autonomously scan a prostate phantom and attached the phantom to a medical robotic arm that mimics the patient's movements. The scanning robot keeps the relative position of the US probe and the prostate constant, ensuring a consistent and robust approach to reconstructing the prostate. To reconstruct the prostate, each slice is segmented to generate a series of prostate contours converted into a 3D point cloud used for biopsy planning. The average scan time of the prostate was 30 s, and the average 3D reconstruction of the prostate took 3 s. We performed four motion scenarios: the phantom was scanned in a stationary state (S), with horizontal motion (H), with vertical motion (V), and with a combination of the two (C). System validation is performed by registering the prostate point cloud reconstructions acquired during different motions (H, V, C) with those obtained in the stationary state. ICP registration with a threshold of 0.8 mm yields mean 83.2\% fitness and 0.35 mm RMSE for S-H registration, 84.1\% fitness and 0.37 mm RMSE for S-V registration and 79.4\% fitness and 0.37 mm RMSE for S-C registration. Due to the elastic and soft material properties of the prostate phantom, the maximum robot tracking error was 3 mm, which can be sufficient for prostate biopsy according to medical literature. The maximum delay in motion compensation was 0.5 s.
title Motion Compensation for Real Time Ultrasound Scanning in Robotically Assisted Prostate Biopsy Procedures
topic Robotics
J.2.7; J.3.3
url https://arxiv.org/abs/2601.05661