Robust Multicentre Detection and Classification of Colorectal Liver Metastases on CT: Application of Foundation Models

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Mali, Shruti Atul, Salahuddin, Zohaib, Zhang, Yumeng, Aichert, Andre, Zhong, Xian, Woodruff, Henry C., Bobowicz, Maciej, Riklund, Katrine, Kupčinskas, Juozas, Faggioni, Lorenzo, Francischello, Roberto, Miclea, Razvan L, Lambin, Philippe
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866918283976900608
author Mali, Shruti Atul
Salahuddin, Zohaib
Zhang, Yumeng
Aichert, Andre
Zhong, Xian
Woodruff, Henry C.
Bobowicz, Maciej
Riklund, Katrine
Kupčinskas, Juozas
Faggioni, Lorenzo
Francischello, Roberto
Miclea, Razvan L
Lambin, Philippe
author_facet Mali, Shruti Atul
Salahuddin, Zohaib
Zhang, Yumeng
Aichert, Andre
Zhong, Xian
Woodruff, Henry C.
Bobowicz, Maciej
Riklund, Katrine
Kupčinskas, Juozas
Faggioni, Lorenzo
Francischello, Roberto
Miclea, Razvan L
Lambin, Philippe
contents Colorectal liver metastases (CRLM) are a major cause of cancer-related mortality, and reliable detection on CT remains challenging in multi-centre settings. We developed a foundation model-based AI pipeline for patient-level classification and lesion-level detection of CRLM on contrast-enhanced CT, integrating uncertainty quantification and explainability. CT data from the EuCanImage consortium (n=2437) and an external TCIA cohort (n=197) were used. Among several pretrained models, UMedPT achieved the best performance and was fine-tuned with an MLP head for classification and an FCOS-based head for lesion detection. The classification model achieved an AUC of 0.90 and a sensitivity of 0.82 on the combined test set, with a sensitivity of 0.85 on the external cohort. Excluding the most uncertain 20 percent of cases improved AUC to 0.91 and balanced accuracy to 0.86. Decision curve analysis showed clinical benefit for threshold probabilities between 0.30 and 0.40. The detection model identified 69.1 percent of lesions overall, increasing from 30 percent to 98 percent across lesion size quartiles. Grad-CAM highlighted lesion-corresponding regions in high-confidence cases. These results demonstrate that foundation model-based pipelines can support robust and interpretable CRLM detection and classification across heterogeneous CT data.
format Preprint
id arxiv_https___arxiv_org_abs_2601_07585
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Robust Multicentre Detection and Classification of Colorectal Liver Metastases on CT: Application of Foundation Models
Mali, Shruti Atul
Salahuddin, Zohaib
Zhang, Yumeng
Aichert, Andre
Zhong, Xian
Woodruff, Henry C.
Bobowicz, Maciej
Riklund, Katrine
Kupčinskas, Juozas
Faggioni, Lorenzo
Francischello, Roberto
Miclea, Razvan L
Lambin, Philippe
Computer Vision and Pattern Recognition
Colorectal liver metastases (CRLM) are a major cause of cancer-related mortality, and reliable detection on CT remains challenging in multi-centre settings. We developed a foundation model-based AI pipeline for patient-level classification and lesion-level detection of CRLM on contrast-enhanced CT, integrating uncertainty quantification and explainability. CT data from the EuCanImage consortium (n=2437) and an external TCIA cohort (n=197) were used. Among several pretrained models, UMedPT achieved the best performance and was fine-tuned with an MLP head for classification and an FCOS-based head for lesion detection. The classification model achieved an AUC of 0.90 and a sensitivity of 0.82 on the combined test set, with a sensitivity of 0.85 on the external cohort. Excluding the most uncertain 20 percent of cases improved AUC to 0.91 and balanced accuracy to 0.86. Decision curve analysis showed clinical benefit for threshold probabilities between 0.30 and 0.40. The detection model identified 69.1 percent of lesions overall, increasing from 30 percent to 98 percent across lesion size quartiles. Grad-CAM highlighted lesion-corresponding regions in high-confidence cases. These results demonstrate that foundation model-based pipelines can support robust and interpretable CRLM detection and classification across heterogeneous CT data.
title Robust Multicentre Detection and Classification of Colorectal Liver Metastases on CT: Application of Foundation Models
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2601.07585