Simulations Predict Improved Valve Performance Without Direct Leaflet Intervention After Neonatal Truncus Arteriosus Repair

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Bornemann, Karoline-Marie, Choi, Perry S., Huber, Jay, Reed, Alexander K., Sharir, Amit, Maskatia, Shiraz A., Marsden, Alison L., Ma, Michael R., Kaiser, Alexander D.
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866914254616002560
author Bornemann, Karoline-Marie
Choi, Perry S.
Huber, Jay
Reed, Alexander K.
Sharir, Amit
Maskatia, Shiraz A.
Marsden, Alison L.
Ma, Michael R.
Kaiser, Alexander D.
author_facet Bornemann, Karoline-Marie
Choi, Perry S.
Huber, Jay
Reed, Alexander K.
Sharir, Amit
Maskatia, Shiraz A.
Marsden, Alison L.
Ma, Michael R.
Kaiser, Alexander D.
contents Truncus arteriosus (TA) is a rare and severe congenital heart disease. Quadricuspid valve morphology occurs in 25% of all TA patients and is linked to regurgitation and increased risk of re-operation. It remains unclear how hemodynamic changes after TA repair alter valve performance. This study simulated pre- and postoperative conditions in a neonatal TA patient to investigate valve performance without direct intervention. We hypothesize that valve performance before and after truncal repair can be predicted in-silico, matching in-vivo imaging and identifying mechanisms how hemodynamic changes after repair will reduce valve regurgitation without direct intervention. Pre- and postoperative CT images of a neonatal patient with quadricuspid valve were segmented. Free edge length and geometric height from the patient's echocardiogram were used to model the valve. For the preoperative condition, ventricular pressures were set equal modeling an unrestricted ventricular septal defect. Systemic and pulmonary resistances were tuned based on the patient's Qp:Qs ratio. For the postoperative condition, boundary conditions were modified to mimic patient-specific hemodynamics after TA repair. The preoperative simulation confirmed mild valve regurgitation seen in-vivo. Interaction between asymmetric flow and surrounding vessel resulted in asymmetric opening and closing. Poor central coaptation led to a central regurgitant jet toward the septum. Altered postoperative hemodynamics improved coaptation and eliminated regurgitation, as seen in-vivo. This modeling approach reproduced in-vivo pre- and postoperative valve performance and identified mechanisms improving coaptation after TA repair. TA repair led to elimination of regurgitation due to enhanced central coaptation. Thus, altered postoperative hemodynamic conditions after TA repair may improve valve performance without direct leaflet intervention.
format Preprint
id arxiv_https___arxiv_org_abs_2601_08932
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Simulations Predict Improved Valve Performance Without Direct Leaflet Intervention After Neonatal Truncus Arteriosus Repair
Bornemann, Karoline-Marie
Choi, Perry S.
Huber, Jay
Reed, Alexander K.
Sharir, Amit
Maskatia, Shiraz A.
Marsden, Alison L.
Ma, Michael R.
Kaiser, Alexander D.
Tissues and Organs
92C35 (Primary), 92C50, 92C32, 76Z05 (Secondary)
J.3.1
Truncus arteriosus (TA) is a rare and severe congenital heart disease. Quadricuspid valve morphology occurs in 25% of all TA patients and is linked to regurgitation and increased risk of re-operation. It remains unclear how hemodynamic changes after TA repair alter valve performance. This study simulated pre- and postoperative conditions in a neonatal TA patient to investigate valve performance without direct intervention. We hypothesize that valve performance before and after truncal repair can be predicted in-silico, matching in-vivo imaging and identifying mechanisms how hemodynamic changes after repair will reduce valve regurgitation without direct intervention. Pre- and postoperative CT images of a neonatal patient with quadricuspid valve were segmented. Free edge length and geometric height from the patient's echocardiogram were used to model the valve. For the preoperative condition, ventricular pressures were set equal modeling an unrestricted ventricular septal defect. Systemic and pulmonary resistances were tuned based on the patient's Qp:Qs ratio. For the postoperative condition, boundary conditions were modified to mimic patient-specific hemodynamics after TA repair. The preoperative simulation confirmed mild valve regurgitation seen in-vivo. Interaction between asymmetric flow and surrounding vessel resulted in asymmetric opening and closing. Poor central coaptation led to a central regurgitant jet toward the septum. Altered postoperative hemodynamics improved coaptation and eliminated regurgitation, as seen in-vivo. This modeling approach reproduced in-vivo pre- and postoperative valve performance and identified mechanisms improving coaptation after TA repair. TA repair led to elimination of regurgitation due to enhanced central coaptation. Thus, altered postoperative hemodynamic conditions after TA repair may improve valve performance without direct leaflet intervention.