Safe Trajectory Gradient Flow Control of a Grid-Interfacing Inverter

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Joswig-Jones, Trager, Zhang, Baosen
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866915732904738816
author Joswig-Jones, Trager
Zhang, Baosen
author_facet Joswig-Jones, Trager
Zhang, Baosen
contents Grid-interfacing inverters serve as the interface between renewable energy resources and the electric power grid, offering fast, programmable control capabilities. However, their operation is constrained by hardware limitations, such as bounds on the current magnitude. Existing control methods for these systems often neglect these constraints during controller design and instead rely on ad hoc limiters, which can introduce instability or degrade performance. In this work, we present a control framework that directly incorporates constraints into the control of a voltage-source inverter. We propose a safe trajectory gradient flow controller, which applies the safe gradient flow method to a rolling horizon trajectory optimization problem to ensure that the states remain within a safe set defined by the constraints while directing the trajectory towards an optimal equilibrium point of a nonlinear program. Simulation results demonstrate that our approach can drive the outputs of a simulated inverter system to optimal values and maintain state constraints, even when using a limited number of optimization steps per control cycle.
format Preprint
id arxiv_https___arxiv_org_abs_2601_10671
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Safe Trajectory Gradient Flow Control of a Grid-Interfacing Inverter
Joswig-Jones, Trager
Zhang, Baosen
Systems and Control
Grid-interfacing inverters serve as the interface between renewable energy resources and the electric power grid, offering fast, programmable control capabilities. However, their operation is constrained by hardware limitations, such as bounds on the current magnitude. Existing control methods for these systems often neglect these constraints during controller design and instead rely on ad hoc limiters, which can introduce instability or degrade performance. In this work, we present a control framework that directly incorporates constraints into the control of a voltage-source inverter. We propose a safe trajectory gradient flow controller, which applies the safe gradient flow method to a rolling horizon trajectory optimization problem to ensure that the states remain within a safe set defined by the constraints while directing the trajectory towards an optimal equilibrium point of a nonlinear program. Simulation results demonstrate that our approach can drive the outputs of a simulated inverter system to optimal values and maintain state constraints, even when using a limited number of optimization steps per control cycle.
title Safe Trajectory Gradient Flow Control of a Grid-Interfacing Inverter
topic Systems and Control
url https://arxiv.org/abs/2601.10671