Measuring Stability Beyond Accuracy in Small Open-Source Medical Large Language Models for Pediatric Endocrinology

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: D'Amario, Vanessa, Daniel, Randy, Zanetti, Alessandro, Edamadaka, Dhruv, Alaparthy, Nitya, Tarkoff, Joshua
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866909993067872256
author D'Amario, Vanessa
Daniel, Randy
Zanetti, Alessandro
Edamadaka, Dhruv
Alaparthy, Nitya
Tarkoff, Joshua
author_facet D'Amario, Vanessa
Daniel, Randy
Zanetti, Alessandro
Edamadaka, Dhruv
Alaparthy, Nitya
Tarkoff, Joshua
contents Small open-source medical large language models (LLMs) offer promising opportunities for low-resource deployment and broader accessibility. However, their evaluation is often limited to accuracy on medical multiple choice question (MCQ) benchmarks, and lacks evaluation of consistency, robustness, or reasoning behavior. We use MCQ coupled to human evaluation and clinical review to assess six small open-source medical LLMs (HuatuoGPT-o1 (Chen 2024), Diabetica-7B, Diabetica-o1 (Wei 2024), Meditron3-8B (Sallinen2025), MedFound-7B (Liu 2025), and ClinicaGPT-base-zh (Wang 2023)) in pediatric endocrinology. In deterministic settings, we examine the effect of prompt variation on models' output and self-assessment bias. In stochastic settings, we evaluate output variability and investigate the relationship between consistency and correctness. HuatuoGPT-o1-8B achieved the highest performance. The results show that high consistency across the model response is not an indicator of correctness, although HuatuoGPT-o1-8B showed the highest consistency rate. When tasked with selecting correct reasoning, both HuatuoGPT-o1-8B and Diabetica-o1 exhibit self-assessment bias and dependency on the order of the candidate explanations. Expert review of incorrect reasoning rationales identified a mix of clinically acceptable responses and clinical oversight. We further show that system-level perturbations, such as differences in CUDA builds, can yield statistically significant shifts in model output despite stable accuracy. This work demonstrates that small, semantically negligible prompt perturbations lead to divergent outputs, raising concerns about reproducibility of LLM-based evaluations and highlights the output variability under different stochastic regimes, emphasizing the need of a broader diagnostic framework to understand potential pitfalls in real-world clinical decision support scenarios.
format Preprint
id arxiv_https___arxiv_org_abs_2601_11567
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Measuring Stability Beyond Accuracy in Small Open-Source Medical Large Language Models for Pediatric Endocrinology
D'Amario, Vanessa
Daniel, Randy
Zanetti, Alessandro
Edamadaka, Dhruv
Alaparthy, Nitya
Tarkoff, Joshua
Computation and Language
Artificial Intelligence
Small open-source medical large language models (LLMs) offer promising opportunities for low-resource deployment and broader accessibility. However, their evaluation is often limited to accuracy on medical multiple choice question (MCQ) benchmarks, and lacks evaluation of consistency, robustness, or reasoning behavior. We use MCQ coupled to human evaluation and clinical review to assess six small open-source medical LLMs (HuatuoGPT-o1 (Chen 2024), Diabetica-7B, Diabetica-o1 (Wei 2024), Meditron3-8B (Sallinen2025), MedFound-7B (Liu 2025), and ClinicaGPT-base-zh (Wang 2023)) in pediatric endocrinology. In deterministic settings, we examine the effect of prompt variation on models' output and self-assessment bias. In stochastic settings, we evaluate output variability and investigate the relationship between consistency and correctness. HuatuoGPT-o1-8B achieved the highest performance. The results show that high consistency across the model response is not an indicator of correctness, although HuatuoGPT-o1-8B showed the highest consistency rate. When tasked with selecting correct reasoning, both HuatuoGPT-o1-8B and Diabetica-o1 exhibit self-assessment bias and dependency on the order of the candidate explanations. Expert review of incorrect reasoning rationales identified a mix of clinically acceptable responses and clinical oversight. We further show that system-level perturbations, such as differences in CUDA builds, can yield statistically significant shifts in model output despite stable accuracy. This work demonstrates that small, semantically negligible prompt perturbations lead to divergent outputs, raising concerns about reproducibility of LLM-based evaluations and highlights the output variability under different stochastic regimes, emphasizing the need of a broader diagnostic framework to understand potential pitfalls in real-world clinical decision support scenarios.
title Measuring Stability Beyond Accuracy in Small Open-Source Medical Large Language Models for Pediatric Endocrinology
topic Computation and Language
Artificial Intelligence
url https://arxiv.org/abs/2601.11567