Test beam performance of a novel RICH detector with timing capabilities for the future ALICE~3 PID system at LHC

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Mazziotta, M. N., Congedo, L., De Robertis, G., Di Mauro, A., Licciulli, F., Lorusso, L., Martinengo, P., Nappi, E., Nicassio, N., Panzarini, G., Pillera, R., Volpe, G.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914263204888576
author Mazziotta, M. N.
Congedo, L.
De Robertis, G.
Di Mauro, A.
Licciulli, F.
Lorusso, L.
Martinengo, P.
Nappi, E.
Nicassio, N.
Panzarini, G.
Pillera, R.
Volpe, G.
author_facet Mazziotta, M. N.
Congedo, L.
De Robertis, G.
Di Mauro, A.
Licciulli, F.
Lorusso, L.
Martinengo, P.
Nappi, E.
Nicassio, N.
Panzarini, G.
Pillera, R.
Volpe, G.
contents The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator and a photosensitive surface based on Silicon Photomultiplier (SiPM) arrays in a proximity-focusing configuration. A thin high-refractive index slab of transparent material (window), acting as a second Cherenkov radiator, is glued on the entrance face of the SiPM arrays to achieve precise charged particle timing. Requiring time matching between aerogel Cherenkov photon and track hits leads to an improvement of pattern recognition by discarding the uncorrelated SiPM dark count hits. In this work we present the current status of the R\&D performed for the ALICE 3 RICH detector prototype and the expected full scale system performance. A special focus will be given to the beam test results obtained with a small-scale prototype instrumented with various array of Hamamatsu SiPMs with pitches ranging from 1 to 3 mm. The Cherenkov radiator consisted of a 2 cm thick aerogel tile with a refractive index of 1.03 at 400 nm wavelength. For timing measurements SiPM arrays coupled with two different window materials (SiO$_2$ and MgF$_2$) were used. The prototype was successfully tested in beam test campaigns at the CERN PS T10 beam line. The data were collected with a complete chain of front-end and readout electronics based on the Petiroc 2A and Radioroc 2 together with a picoTDC to measure charges and times. We measured a charged particle detection efficiency above 99\% and a single photon angular resolution better than 4.2 mrad at the Cherenkov angle saturation with a time resolution better than 70 ps for charged particles.
format Preprint
id arxiv_https___arxiv_org_abs_2601_12492
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Test beam performance of a novel RICH detector with timing capabilities for the future ALICE~3 PID system at LHC
Mazziotta, M. N.
Congedo, L.
De Robertis, G.
Di Mauro, A.
Licciulli, F.
Lorusso, L.
Martinengo, P.
Nappi, E.
Nicassio, N.
Panzarini, G.
Pillera, R.
Volpe, G.
Instrumentation and Detectors
High Energy Physics - Experiment
The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator and a photosensitive surface based on Silicon Photomultiplier (SiPM) arrays in a proximity-focusing configuration. A thin high-refractive index slab of transparent material (window), acting as a second Cherenkov radiator, is glued on the entrance face of the SiPM arrays to achieve precise charged particle timing. Requiring time matching between aerogel Cherenkov photon and track hits leads to an improvement of pattern recognition by discarding the uncorrelated SiPM dark count hits. In this work we present the current status of the R\&D performed for the ALICE 3 RICH detector prototype and the expected full scale system performance. A special focus will be given to the beam test results obtained with a small-scale prototype instrumented with various array of Hamamatsu SiPMs with pitches ranging from 1 to 3 mm. The Cherenkov radiator consisted of a 2 cm thick aerogel tile with a refractive index of 1.03 at 400 nm wavelength. For timing measurements SiPM arrays coupled with two different window materials (SiO$_2$ and MgF$_2$) were used. The prototype was successfully tested in beam test campaigns at the CERN PS T10 beam line. The data were collected with a complete chain of front-end and readout electronics based on the Petiroc 2A and Radioroc 2 together with a picoTDC to measure charges and times. We measured a charged particle detection efficiency above 99\% and a single photon angular resolution better than 4.2 mrad at the Cherenkov angle saturation with a time resolution better than 70 ps for charged particles.
title Test beam performance of a novel RICH detector with timing capabilities for the future ALICE~3 PID system at LHC
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2601.12492