Dosimetry for Proton Therapy Using a β-Ga$_2$O$_3$ Metal-Semiconductor-Metal Detector with Low-Noise Amplification

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Ellis, Hunter D., Mallapillai, Ajayvarman, Miller, Jared, Rahaman, Imteaz, Li, Botong, Sarkar, Vikren, Fu, Kai
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911389054926848
author Ellis, Hunter D.
Mallapillai, Ajayvarman
Miller, Jared
Rahaman, Imteaz
Li, Botong
Sarkar, Vikren
Fu, Kai
author_facet Ellis, Hunter D.
Mallapillai, Ajayvarman
Miller, Jared
Rahaman, Imteaz
Li, Botong
Sarkar, Vikren
Fu, Kai
contents Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue, leading to improved patient outcomes and reduced side effects compared to traditional X-ray therapy. To ensure patient safety, each treatment plan must be experimentally validated before clinical implementation. However, current dosimetry devices face limitations in performing angled beam measurements and obtaining multi-depth assessments, both of which are essential for verifying IMPT treatment plans. In this study, the performance of a β-Ga$_2$O$_3$-based metal-semiconductor-metal (MSM) detector with a low-noise amplifier is studied and evaluated under various proton radiation doses and energy levels delivered by a MEVION S250i proton accelerator. The detector performance is also compared with that of an ionization chamber. The β-Ga$_2$O$_3$ detector exhibits a linear response with proton dose for single-spot irradiations, and its response to varying proton energies closely matches both the ion chamber data and simulated dose distributions. These findings highlight the potential of β-Ga$_2$O$_3$-based detectors as robust dosimetry devices for IMPT applications.
format Preprint
id arxiv_https___arxiv_org_abs_2601_14654
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Dosimetry for Proton Therapy Using a β-Ga$_2$O$_3$ Metal-Semiconductor-Metal Detector with Low-Noise Amplification
Ellis, Hunter D.
Mallapillai, Ajayvarman
Miller, Jared
Rahaman, Imteaz
Li, Botong
Sarkar, Vikren
Fu, Kai
Medical Physics
Materials Science
Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue, leading to improved patient outcomes and reduced side effects compared to traditional X-ray therapy. To ensure patient safety, each treatment plan must be experimentally validated before clinical implementation. However, current dosimetry devices face limitations in performing angled beam measurements and obtaining multi-depth assessments, both of which are essential for verifying IMPT treatment plans. In this study, the performance of a β-Ga$_2$O$_3$-based metal-semiconductor-metal (MSM) detector with a low-noise amplifier is studied and evaluated under various proton radiation doses and energy levels delivered by a MEVION S250i proton accelerator. The detector performance is also compared with that of an ionization chamber. The β-Ga$_2$O$_3$ detector exhibits a linear response with proton dose for single-spot irradiations, and its response to varying proton energies closely matches both the ion chamber data and simulated dose distributions. These findings highlight the potential of β-Ga$_2$O$_3$-based detectors as robust dosimetry devices for IMPT applications.
title Dosimetry for Proton Therapy Using a β-Ga$_2$O$_3$ Metal-Semiconductor-Metal Detector with Low-Noise Amplification
topic Medical Physics
Materials Science
url https://arxiv.org/abs/2601.14654