Reliable Quasi-Static Post-Fall Floor-Occupancy Detection Using Low-Cost Millimetre-Wave Radar

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Trinh, Huy, Thai, Phuong, Creager, Elliot, Shaker, George
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914277862932480
author Trinh, Huy
Thai, Phuong
Creager, Elliot
Shaker, George
author_facet Trinh, Huy
Thai, Phuong
Creager, Elliot
Shaker, George
contents As the population ages rapidly, long-term care (LTC) facilities across North America face growing pressure to monitor residents safely while keeping staff workload manageable. Falls are among the most critical events to monitor due to their timely response requirement, yet frequent false alarms or uncertain detections can overwhelm caregivers and contribute to alarm fatigue. This motivates the design of reliable, whole end-to-end ambient monitoring systems from occupancy and activity awareness to fall and post-fall detection. In this paper, we focus on robust post-fall floor-occupancy detection using an off-the-shelf 60 GHz FMCW radar and evaluate its deployment in a realistic, furnished indoor environment representative of LTC facilities. Post-fall detection is challenging since motion is minimal, and reflections from the floor and surrounding objects can dominate the radar signal return. We compare a vendor-provided digital beamforming (DBF) pipeline against a proposed preprocessing approach based on Capon or minimum variance distortionless response (MVDR) beamforming. A cell-averaging constant false alarm rate (CA-CFAR) detector is applied and evaluated on the resulting range-azimuth maps across 7 participants. The proposed method improves the mean frame-positive rate from 0.823 (DBF) to 0.916 (Proposed).
format Preprint
id arxiv_https___arxiv_org_abs_2601_17710
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Reliable Quasi-Static Post-Fall Floor-Occupancy Detection Using Low-Cost Millimetre-Wave Radar
Trinh, Huy
Thai, Phuong
Creager, Elliot
Shaker, George
Signal Processing
As the population ages rapidly, long-term care (LTC) facilities across North America face growing pressure to monitor residents safely while keeping staff workload manageable. Falls are among the most critical events to monitor due to their timely response requirement, yet frequent false alarms or uncertain detections can overwhelm caregivers and contribute to alarm fatigue. This motivates the design of reliable, whole end-to-end ambient monitoring systems from occupancy and activity awareness to fall and post-fall detection. In this paper, we focus on robust post-fall floor-occupancy detection using an off-the-shelf 60 GHz FMCW radar and evaluate its deployment in a realistic, furnished indoor environment representative of LTC facilities. Post-fall detection is challenging since motion is minimal, and reflections from the floor and surrounding objects can dominate the radar signal return. We compare a vendor-provided digital beamforming (DBF) pipeline against a proposed preprocessing approach based on Capon or minimum variance distortionless response (MVDR) beamforming. A cell-averaging constant false alarm rate (CA-CFAR) detector is applied and evaluated on the resulting range-azimuth maps across 7 participants. The proposed method improves the mean frame-positive rate from 0.823 (DBF) to 0.916 (Proposed).
title Reliable Quasi-Static Post-Fall Floor-Occupancy Detection Using Low-Cost Millimetre-Wave Radar
topic Signal Processing
url https://arxiv.org/abs/2601.17710