Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Nagai, Yutaro, Enoto, Teruaki, Tsujimoto, Masahiro, Yamaguchi, Hiroya, Mochizuki, Yuto, Behar, Ehud, Corrales, Lia, Draghis, Paul A., Ebisawa, Ken, Hell, Natalie, Kallman, Timothy R., Kelley, Richard L., Pradhan, Pragati, Yamada, Shinya, Azuma, Toshiyuki, Tong, Xiao-Min
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914278003441664
author Nagai, Yutaro
Enoto, Teruaki
Tsujimoto, Masahiro
Yamaguchi, Hiroya
Mochizuki, Yuto
Behar, Ehud
Corrales, Lia
Draghis, Paul A.
Ebisawa, Ken
Hell, Natalie
Kallman, Timothy R.
Kelley, Richard L.
Pradhan, Pragati
Yamada, Shinya
Azuma, Toshiyuki
Tong, Xiao-Min
author_facet Nagai, Yutaro
Enoto, Teruaki
Tsujimoto, Masahiro
Yamaguchi, Hiroya
Mochizuki, Yuto
Behar, Ehud
Corrales, Lia
Draghis, Paul A.
Ebisawa, Ken
Hell, Natalie
Kallman, Timothy R.
Kelley, Richard L.
Pradhan, Pragati
Yamada, Shinya
Azuma, Toshiyuki
Tong, Xiao-Min
contents The Fe K$α$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of $\sim$0.2 eV, equivalent to a line-of-sight velocity of $\sim$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$α$ line shifts redward by $\sim$4 eV as $q$ increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$β$ line at 7.06 keV shifts blueward by $\sim$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$α$ and K$β$ line provides a robust estimate of $q$ by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$α$, K$β$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$α$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.
format Preprint
id arxiv_https___arxiv_org_abs_2601_17792
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3
Nagai, Yutaro
Enoto, Teruaki
Tsujimoto, Masahiro
Yamaguchi, Hiroya
Mochizuki, Yuto
Behar, Ehud
Corrales, Lia
Draghis, Paul A.
Ebisawa, Ken
Hell, Natalie
Kallman, Timothy R.
Kelley, Richard L.
Pradhan, Pragati
Yamada, Shinya
Azuma, Toshiyuki
Tong, Xiao-Min
High Energy Astrophysical Phenomena
The Fe K$α$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of $\sim$0.2 eV, equivalent to a line-of-sight velocity of $\sim$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$α$ line shifts redward by $\sim$4 eV as $q$ increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$β$ line at 7.06 keV shifts blueward by $\sim$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$α$ and K$β$ line provides a robust estimate of $q$ by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$α$, K$β$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$α$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.
title Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3
topic High Energy Astrophysical Phenomena
url https://arxiv.org/abs/2601.17792