Transportability of Regression Calibration with External Validation Studies for Measurement Error Correction

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Li, Zexiang, Spiegelman, Donna, Wang, Molin, Wang, Zuoheng, Zhou, Xin
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914279982104576
author Li, Zexiang
Spiegelman, Donna
Wang, Molin
Wang, Zuoheng
Zhou, Xin
author_facet Li, Zexiang
Spiegelman, Donna
Wang, Molin
Wang, Zuoheng
Zhou, Xin
contents In nutritional and environmental epidemiology, exposures are impractical to measure accurately, while practical measures for these exposures are often subject to substantial measurement error. Regression calibration is among the most used measurement error correction methods with external validation studies. The use of external studies to assess the measurement error process always carries the risk of introducing estimation bias into the main study analysis. Although the transportability of regression calibration is usually assumed for practical epidemiology studies, it has not been well studied. In this work, under the measurement error process with a mixture of Berkson-like and classical-like errors, we investigate conditions under which the effect estimate from regression calibration with an external validation study is unbiased for the association between exposure and health outcome. We further examine departures from the transportability assumption, under which the regression calibration estimator is itself biased. However, we theoretically prove that, in most cases, it yields lower bias than the naive method. The derived conditions are confirmed through simulation studies and further verified in an example investigating the association between the risk of cardiovascular disease and moderate physical activity in the health professional follow-up study.
format Preprint
id arxiv_https___arxiv_org_abs_2601_17961
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Transportability of Regression Calibration with External Validation Studies for Measurement Error Correction
Li, Zexiang
Spiegelman, Donna
Wang, Molin
Wang, Zuoheng
Zhou, Xin
Methodology
In nutritional and environmental epidemiology, exposures are impractical to measure accurately, while practical measures for these exposures are often subject to substantial measurement error. Regression calibration is among the most used measurement error correction methods with external validation studies. The use of external studies to assess the measurement error process always carries the risk of introducing estimation bias into the main study analysis. Although the transportability of regression calibration is usually assumed for practical epidemiology studies, it has not been well studied. In this work, under the measurement error process with a mixture of Berkson-like and classical-like errors, we investigate conditions under which the effect estimate from regression calibration with an external validation study is unbiased for the association between exposure and health outcome. We further examine departures from the transportability assumption, under which the regression calibration estimator is itself biased. However, we theoretically prove that, in most cases, it yields lower bias than the naive method. The derived conditions are confirmed through simulation studies and further verified in an example investigating the association between the risk of cardiovascular disease and moderate physical activity in the health professional follow-up study.
title Transportability of Regression Calibration with External Validation Studies for Measurement Error Correction
topic Methodology
url https://arxiv.org/abs/2601.17961