Classifier Calibration at Scale: An Empirical Study of Model-Agnostic Post-Hoc Methods

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Manokhin, Valery, Grønhaug, Daniel
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917226869686272
author Manokhin, Valery
Grønhaug, Daniel
author_facet Manokhin, Valery
Grønhaug, Daniel
contents We study model-agnostic post-hoc calibration methods intended to improve probabilistic predictions in supervised binary classification on real i.i.d. tabular data, with particular emphasis on conformal and Venn-based approaches that provide distribution-free validity guarantees under exchangeability. We benchmark 21 widely used classifiers, including linear models, SVMs, tree ensembles (CatBoost, XGBoost, LightGBM), and modern tabular neural and foundation models, on binary tasks from the TabArena-v0.1 suite using randomized, stratified five-fold cross-validation with a held-out test fold. Five calibrators; Isotonic regression, Platt scaling, Beta calibration, Venn-Abers predictors, and Pearsonify are trained on a separate calibration split and applied to test predictions. Calibration is evaluated using proper scoring rules (log-loss and Brier score) and diagnostic measures (Spiegelhalter's Z, ECE, and ECI), alongside discrimination (AUC-ROC) and standard classification metrics. Across tasks and architectures, Venn-Abers predictors achieve the largest average reductions in log-loss, followed closely by Beta calibration, while Platt scaling exhibits weaker and less consistent effects. Beta calibration improves log-loss most frequently across tasks, whereas Venn-Abers displays fewer instances of extreme degradation and slightly more instances of extreme improvement. Importantly, we find that commonly used calibration procedures, most notably Platt scaling and isotonic regression, can systematically degrade proper scoring performance for strong modern tabular models. Overall classification performance is often preserved, but calibration effects vary substantially across datasets and architectures, and no method dominates uniformly. In expectation, all methods except Pearsonify slightly increase accuracy, but the effect is marginal, with the largest expected gain about 0.008%.
format Preprint
id arxiv_https___arxiv_org_abs_2601_19944
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Classifier Calibration at Scale: An Empirical Study of Model-Agnostic Post-Hoc Methods
Manokhin, Valery
Grønhaug, Daniel
Machine Learning
Applications
68T05, 62H30, 62F15, 62G05, 68T01
I.2.6; I.5.1; I.5.2; I.2.10; H.2.8
We study model-agnostic post-hoc calibration methods intended to improve probabilistic predictions in supervised binary classification on real i.i.d. tabular data, with particular emphasis on conformal and Venn-based approaches that provide distribution-free validity guarantees under exchangeability. We benchmark 21 widely used classifiers, including linear models, SVMs, tree ensembles (CatBoost, XGBoost, LightGBM), and modern tabular neural and foundation models, on binary tasks from the TabArena-v0.1 suite using randomized, stratified five-fold cross-validation with a held-out test fold. Five calibrators; Isotonic regression, Platt scaling, Beta calibration, Venn-Abers predictors, and Pearsonify are trained on a separate calibration split and applied to test predictions. Calibration is evaluated using proper scoring rules (log-loss and Brier score) and diagnostic measures (Spiegelhalter's Z, ECE, and ECI), alongside discrimination (AUC-ROC) and standard classification metrics. Across tasks and architectures, Venn-Abers predictors achieve the largest average reductions in log-loss, followed closely by Beta calibration, while Platt scaling exhibits weaker and less consistent effects. Beta calibration improves log-loss most frequently across tasks, whereas Venn-Abers displays fewer instances of extreme degradation and slightly more instances of extreme improvement. Importantly, we find that commonly used calibration procedures, most notably Platt scaling and isotonic regression, can systematically degrade proper scoring performance for strong modern tabular models. Overall classification performance is often preserved, but calibration effects vary substantially across datasets and architectures, and no method dominates uniformly. In expectation, all methods except Pearsonify slightly increase accuracy, but the effect is marginal, with the largest expected gain about 0.008%.
title Classifier Calibration at Scale: An Empirical Study of Model-Agnostic Post-Hoc Methods
topic Machine Learning
Applications
68T05, 62H30, 62F15, 62G05, 68T01
I.2.6; I.5.1; I.5.2; I.2.10; H.2.8
url https://arxiv.org/abs/2601.19944