Optimising Re-entrant Cavity Designs for Low Mass Axion Haloscopes

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Singh, Raj Aryan, Taylor, Paige Rose, Hartmann, Elrina, Brooks, Geoffrey, McAllister, Ben T.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910003153076224
author Singh, Raj Aryan
Taylor, Paige Rose
Hartmann, Elrina
Brooks, Geoffrey
McAllister, Ben T.
author_facet Singh, Raj Aryan
Taylor, Paige Rose
Hartmann, Elrina
Brooks, Geoffrey
McAllister, Ben T.
contents Axion haloscopes provide a leading experimental approach to detecting QCD axion dark matter through resonant axion-photon conversion in microwave cavities. Extending haloscope sensitivity to low axion masses remains challenging due to the large resonator volumes required at sub-GHz frequencies. Re-entrant cavities offer a compact solution, but their performance depends strongly on geometric optimisation. We present a comprehensive finite-element study of re-entrant cavity haloscope designs operating in the 100 to 500 MHz range, comparing their performance using effective scan time as a figure of merit. Among the configurations studied, we identify a double attack geometry that achieves a roughly threefold improvement in effective scan time compared to a conventional single-rod re-entrant cavity. We further investigate practical implementation strategies, including a hybrid design employing one fixed rod and one tunable rod, which preserves a scan time gain while reducing mechanical complexity. These results demonstrate a pathway to enhanced low-mass axion haloscope sensitivity.
format Preprint
id arxiv_https___arxiv_org_abs_2601_20151
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Optimising Re-entrant Cavity Designs for Low Mass Axion Haloscopes
Singh, Raj Aryan
Taylor, Paige Rose
Hartmann, Elrina
Brooks, Geoffrey
McAllister, Ben T.
Instrumentation and Detectors
Axion haloscopes provide a leading experimental approach to detecting QCD axion dark matter through resonant axion-photon conversion in microwave cavities. Extending haloscope sensitivity to low axion masses remains challenging due to the large resonator volumes required at sub-GHz frequencies. Re-entrant cavities offer a compact solution, but their performance depends strongly on geometric optimisation. We present a comprehensive finite-element study of re-entrant cavity haloscope designs operating in the 100 to 500 MHz range, comparing their performance using effective scan time as a figure of merit. Among the configurations studied, we identify a double attack geometry that achieves a roughly threefold improvement in effective scan time compared to a conventional single-rod re-entrant cavity. We further investigate practical implementation strategies, including a hybrid design employing one fixed rod and one tunable rod, which preserves a scan time gain while reducing mechanical complexity. These results demonstrate a pathway to enhanced low-mass axion haloscope sensitivity.
title Optimising Re-entrant Cavity Designs for Low Mass Axion Haloscopes
topic Instrumentation and Detectors
url https://arxiv.org/abs/2601.20151